Disintegration rate and gamma-ray emission probability per decay measurement of Cu-64

dc.contributor.authorKOSKINAS, M.F.
dc.contributor.authorYAMAZAKI, I.M.
dc.contributor.authorMOREIRA, D.S.
dc.contributor.authorTAKEDA, M.N.
dc.contributor.authorDIAS, M.S.
dc.coverageInternacionalpt_BR
dc.creator.evento60 YEARS OF IEA-R1: INTERNATIONAL WORKSHOP ON UTILIZATION OF RESEARCH REACTORSpt_BR
dc.date.accessioned2018-03-19T11:24:40Z
dc.date.available2018-03-19T11:24:40Z
dc.date.eventoNovember 28 - December 01, 2017pt_BR
dc.description.abstractThis work aims to present the 64Cu standardization method developed in the Nuclear Metrology Laboratory (LMN) at the IPEN-CNEN/SP, using a 4 􀀀 coincidence system, and the measurement of the gamma-ray emission probabilities per decay of 1345.7 keV of 64Cu by means of a REGe gamma-ray spectrometer. The 4 􀀀 coincidence system consists of a gas- flow proportional counter with 4 geometry and using 90% Ar + 10% CH4 gas at 0.1 MPa, as the detector, coupled to two NaI(Tl) crystal for the gamma-ray emission detection. The events were registered by means of a Time to Amplitude Converter (TAC) associated with a Multi-Channel Analyzer. Two gamma-ray windows were set for the coincidence measurements, one including the positron-annihilation quanta and the other located at the total absorption energy peak of the 1345.7 keV gamma-ray transition. The 64Cu was obtained by irradiating 0.3mg of metallic cooper in the IEA-R1 research reactor under a 1 1013 cm􀀀2 s􀀀1 thermal neutrons flux. To obtain the 64Cu solution the foil irradiated was dissolved in 20 L of HNO3 65% and after that was diluted in 20 mL of 0.1M HCl. The activity was determined by means of the extrapolation curve from eight irradiations, normalized by means of the germanium measurements. The Kawada factor to correct the inefficiency for beta plus and beta minus in the N4 has been applied. The gamma-ray full efficiency peak curve of the germanium spectrometer was measured at 17.9 cm of source-detector distance, in the energy range from 244 keV to 2754 keV, by measuring flamed-sealed ampoules of 24Na, 60Co, 133Ba, 137Cs, and 152Eu standardized at the LMN. The sample for measurement in the spectrometer was prepared in flame-sealed ampoule with 1 mL of the diluted solution. The gamma-ray emission probability per decay of the 1345.7 keV transition of 64 Cu was (0.472 0.010)%, in agreement with the literature.pt_BR
dc.format.extent55-55pt_BR
dc.identifier.citationKOSKINAS, M.F.; YAMAZAKI, I.M.; MOREIRA, D.S.; TAKEDA, M.N.; DIAS, M.S. Disintegration rate and gamma-ray emission probability per decay measurement of Cu-64. In: 60 YEARS OF IEA-R1: INTERNATIONAL WORKSHOP ON UTILIZATION OF RESEARCH REACTORS, November 28 - December 01, 2017, São Paulo, SP. <b>Abstract...</b> São Paulo, SP: Instituto de Pesquisas Energéticas e Nucleares, 2017. p. 55-55. Disponível em: http://repositorio.ipen.br/handle/123456789/28752.
dc.identifier.orcidhttps://orcid.org/0000-0003-2478-5757
dc.identifier.orcidhttps://orcid.org/0000-0001-8407-9833
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28752
dc.localSão Paulo, SPpt_BR
dc.local.eventoSão Paulo, SPpt_BR
dc.publisherInstituto de Pesquisas Energéticas e Nuclearespt_BR
dc.rightsopenAccesspt_BR
dc.subjectcoincidence methods
dc.subjectcopper 64
dc.subjectemission
dc.subjectgamma radiation
dc.subjectgamma spectrometers
dc.subjectmulti-channel analyzers
dc.subjectstandardization
dc.subjecttantalum carbides
dc.titleDisintegration rate and gamma-ray emission probability per decay measurement of Cu-64pt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorMAURO NORIAKI TAKEDA
ipen.autorMAURO DA SILVA DIAS
ipen.autorDENISE SIMÕES MOREIRA
ipen.autorIONE MAKIKO YAMAZAKI
ipen.autorMARINA FALLONE KOSKINAS
ipen.codigoautor2379
ipen.codigoautor1292
ipen.codigoautor2109
ipen.codigoautor195
ipen.codigoautor1387
ipen.contributor.ipenauthorMAURO NORIAKI TAKEDA
ipen.contributor.ipenauthorMAURO DA SILVA DIAS
ipen.contributor.ipenauthorDENISE SIMÕES MOREIRA
ipen.contributor.ipenauthorIONE MAKIKO YAMAZAKI
ipen.contributor.ipenauthorMARINA FALLONE KOSKINAS
ipen.date.recebimento18-03pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc24574pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication510a1aa3-c6b8-43ac-b2f2-5378657ac6e2
relation.isAuthorOfPublication58653850-db59-4051-aa72-5c32a5f6670e
relation.isAuthorOfPublication0b07b50e-fca7-4c8f-8f83-7926896d0b4c
relation.isAuthorOfPublication897eceb4-2404-4215-b1b0-dfd4cbb1ecee
relation.isAuthorOfPublication420a8816-64da-4bb8-a1c4-5b8b638033b1
relation.isAuthorOfPublication.latestForDiscovery420a8816-64da-4bb8-a1c4-5b8b638033b1
sigepi.autor.atividadeKOSKINAS, M.F.:1387:310:Spt_BR
sigepi.autor.atividadeYAMAZAKI, I.M.:195:310:Npt_BR
sigepi.autor.atividadeMOREIRA, D.S.:2109:310:Npt_BR
sigepi.autor.atividadeTAKEDA, M.N.:2379:310:Npt_BR
sigepi.autor.atividadeDIAS, M.S.:1292:310:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24574.pdf
Tamanho:
86.28 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: