A-type apatite/ESR dosimetry in the therapy dose level to photons

dc.contributor.authorOLIVEIRA, L.M.pt_BR
dc.contributor.authorRODRIGUES, L.N.pt_BR
dc.coverageNacionalpt_BR
dc.date.accessioned2014-07-30T17:21:30Zpt_BR
dc.date.accessioned2014-07-30T19:00:15Z
dc.date.available2014-07-30T17:21:30Zpt_BR
dc.date.available2014-07-30T19:00:15Z
dc.date.issued2002pt_BR
dc.description.abstractIn this report is evaluated the response of the apatite powder ESR dosimeter irradiated with 60Co photons in the 0.2-100 Gy range. The specific material was developed in a previous systematic study, which established the correlation between synthesis process, structural and dosimetric properties ofthe A-type synthetic apatite. An excellent linear fit was obtained to the dose response in the therapy leveI. Sources of the uncertainty intrinsic to the dosimeter and to the ESR technique was evaluated showing the excellent precision leveI achievable with the apatite powder dosimeter. Improvements can be performed to increase dosimeter accuracy.
dc.format.extent950-953pt_BR
dc.identifier.citationOLIVEIRA, L.M.; RODRIGUES, L.N. A-type apatite/ESR dosimetry in the therapy dose level to photons. <b>Revista Brasileira de Pesquisa e Desenvolvimento</b>, v. 4, n. 3, p. 950-953, 2002. Parte 1. Disponível em: http://repositorio.ipen.br/handle/123456789/5979.
dc.identifier.fasciculo3pt_BR
dc.identifier.issn0104-7698pt_BR
dc.identifier.suplementoParte 1pt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5979pt_BR
dc.identifier.vol4pt_BR
dc.relation.ispartofRevista Brasileira de Pesquisa e Desenvolvimentopt_BR
dc.rightsopenAccessen
dc.sourceApresentado tambem em: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING ON NUCLEAR APPLICATIONS, 6th, Aug. 11-16, 2002, Rio de Janeiro, RJpt_BR
dc.subjectdosimetrypt_BR
dc.subjectdosemeterspt_BR
dc.subjectapatitespt_BR
dc.subjectcalcium phosphatespt_BR
dc.subjectelectron spin resonancept_BR
dc.subjectcobalt 60pt_BR
dc.subjectradiotherapypt_BR
dc.titleA-type apatite/ESR dosimetry in the therapy dose level to photonspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLAURA NATAL RODRIGUES
ipen.codigoautor324
ipen.contributor.ipenauthorLAURA NATAL RODRIGUES
ipen.date.recebimento03-11pt_BR
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc09367pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication11143e67-5715-4371-8f83-c77802e0ef1c
relation.isAuthorOfPublication.latestForDiscovery11143e67-5715-4371-8f83-c77802e0ef1c
sigepi.autor.atividadeRODRIGUES, L.N.:324:28:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
09367.pdf
Tamanho:
3.91 MB
Formato:
Adobe Portable Document Format

Coleções