Electronic brachytherapy

dc.contributor.authorDIAS, F. S.
dc.contributor.authorRODRIGUES JR, O.
dc.contributor.authorPOTIENS, M. P. A.
dc.coverageInternacional
dc.date.accessioned2026-05-15T15:03:27Z
dc.date.available2026-05-15T15:03:27Z
dc.date.issued2026
dc.description.abstractNew radiotherapy techniques have been innovative in recent decades with the aim of maximizing the dose to tumor tissue and reducing the dose to healthy tissue. One of the modalities that has gained prominence, using low-energy beams, is intraoperative radiotherapy (IORT), as it is a method based on high radiation doses (10–20 Gy) administered to the tumor bed immediately after surgical excision. IORT can be achieved through treatment with low-energy X-ray beams with some devices available on the market. However, such devices provide little dosimetric information and lack a calibration protocol. According to the recently updated recommendations of the TRS 398 standard (2024), for the use of low-energy beams, the ideal is to use a parallel plate ionization chamber calibrated in terms of absorbed dose in water. Based on TRS 398, this work established a calibration protocol for parallel plate dosimeters in terms of absorbed dose in water at the Center for Ionizing Radiation Metrology (CEMRI) of the Institute for Energy and Nuclear Research (IPEN).
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIDFAPESP:18/05982-0
dc.description.sponsorshipIDCNPq:140965/2021-1
dc.format.extent1-15
dc.identifier.citationDIAS, F. S.; RODRIGUES JR, O.; POTIENS, M. P. A. Electronic brachytherapy: a calibration protocol in terms of absorbed dose to water. <b>Brazilian Journal of Radiation Sciences</b>, v. 14, n. 1, p. 1-15, 2026. DOI: <a href="https://dx.doi.org/10.15392/2319-0612.2026.2992">10.15392/2319-0612.2026.2992</a>. Disponível em: https://repositorio.ipen.br/handle/123456789/49876.
dc.identifier.doi10.15392/2319-0612.2026.2992
dc.identifier.fasciculo1
dc.identifier.issn2319-0612
dc.identifier.orcidhttps://orcid.org/0000-0002-6704-1910
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.percentilfiSem Percentil F.I.
dc.identifier.percentilfiCiteScoreSem Percentil CiteScore
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/49876
dc.identifier.vol14
dc.language.isoeng
dc.relation.ispartofBrazilian Journal of Radiation Sciences
dc.rightsopenAccess
dc.titleElectronic brachytherapy
dc.title.alternativeBraquiterapia eletrônica: protocolo de calibração em termos da dose absorvida na água
dc.typeArtigo de periódico
dspace.entity.typePublication
ipen.autorFABIO SABARA DIAS
ipen.autorORLANDO RODRIGUES JUNIOR
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.codigoautor15622
ipen.codigoautor322
ipen.codigoautor346
ipen.contributor.ipenauthorFABIO SABARA DIAS
ipen.contributor.ipenauthorORLANDO RODRIGUES JUNIOR
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.identifier.fiSem F.I.
ipen.identifier.fiCiteScoreSem CiteScore
ipen.identifier.ipendoc31963
ipen.subtituloa calibration protocol in terms of absorbed dose to water
ipen.type.genreArtigo
relation.isAuthorOfPublicationdc2fb195-8591-445f-b160-18de69cca360
relation.isAuthorOfPublicationf72d59d1-f942-442a-b16e-8b0ba0e2b671
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication.latestForDiscoverydc2fb195-8591-445f-b160-18de69cca360
sigepi.autor.atividadeFABIO SABARA DIAS:15622:330:N
sigepi.autor.atividadeORLANDO RODRIGUES JUNIOR:322:330:N
sigepi.autor.atividadeMARIA DA PENHA ALBUQUERQUE POTIENS:346:330:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2319-0612-bjrs-v14n1-lote0626-2992.pdf
Tamanho:
464.53 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções