The use of personal protection equipment for the absorbed doses of eye lens and thyroid gland in CBCT exams using Monte Carlo

dc.contributor.authorSOARES, MARIA R.pt_BR
dc.contributor.authorSANTOS, WILLIAM S.pt_BR
dc.contributor.authorNEVES, LUCIO P.pt_BR
dc.contributor.authorPERINI, ANA P.pt_BR
dc.contributor.authorBATISTA, WILSON O.G.pt_BR
dc.contributor.authorMAIA, ANA F.pt_BR
dc.contributor.authorBELINATO, WALMIRpt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2020-10-15T19:22:13Z
dc.date.available2020-10-15T19:22:13Z
dc.date.issued2020pt_BR
dc.description.abstractThe purpose of this study was to evaluate the absorbed dose in the thyroid and eye lens when the patient uses individual protection. For this purpose, Monte Carlo (MC) simulation was employed using five different field of view (FOV) sizes, available in the i-Cat classic CBCT equipment. To represent the patient, a male virtual anthropomorphic phantom was used. Three different models of lead eyewear and thyroid shield were evaluated, as well as the dose difference with and without the personal protection equipment. The difference in the absorbed dose in relation to the use of the lead eyewear presented a reduction of 19% for the 8 cm×6 cm FOV (diameter×height), and 73% for the 14 cm×22 cm FOV. In relation to the thyroid, only the shield that involved the whole neck contributed to the reduction of the absorbed dose by up to 72% for a 14 cm×22 cm FOV. For the thyroid shields there was a maximum increase of 59% (14 cm×6 cm FOV), consequently, increasing the effective dose for the protocol. The results showed that the lead eyewear contributed to the protection of the eye lens, but the efficiency of the thyroid shield depends on several factors, as FOV and shield model.pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipIDFAPEMIG: APQ-03049-15; APQ-02934-15pt_BR
dc.description.sponsorshipIDCNPq: 421603/2016-0; 420699/2016-3; 168947/2017-0; 150525/2016-8; 30135/2016-8pt_BR
dc.format.extent1-6pt_BR
dc.identifier.citationSOARES, MARIA R.; SANTOS, WILLIAM S.; NEVES, LUCIO P.; PERINI, ANA P.; BATISTA, WILSON O.G.; MAIA, ANA F.; BELINATO, WALMIR; CALDAS, LINDA V.E. The use of personal protection equipment for the absorbed doses of eye lens and thyroid gland in CBCT exams using Monte Carlo. <b>Radiation Physics and Chemistry</b>, v. 167, p. 1-6, 2020. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2019.108347">10.1016/j.radphyschem.2019.108347</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/31442.
dc.identifier.doi10.1016/j.radphyschem.2019.108347pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.percentilfi66.43pt_BR
dc.identifier.percentilfiCiteScore72.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/31442
dc.identifier.vol167pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.sourceInternational Symposium on Radiation Physics, 14th, October 07-11, 2018, Cordoba, Argentinapt_BR
dc.subjectradiation protection
dc.subjectcomputerized tomography
dc.subjectmonte carlo method
dc.subjectsimulation
dc.subjectprotective clothing
dc.subjectequipment
dc.subjecteyes
dc.subjectphantoms
dc.subjectneck
dc.titleThe use of personal protection equipment for the absorbed doses of eye lens and thyroid gland in CBCT exams using Monte Carlopt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorWILLIAM DE SOUZA SANTOS
ipen.autorLINDA V. E. CALDAS
ipen.autorMARIA ROSANGELA SOARES
ipen.codigoautor12113
ipen.codigoautor1495
ipen.codigoautor14289
ipen.contributor.ipenauthorWILLIAM DE SOUZA SANTOS
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorMARIA ROSANGELA SOARES
ipen.date.recebimento20-10
ipen.identifier.fi2.858pt_BR
ipen.identifier.fiCiteScore3.8
ipen.identifier.ipendoc27216pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublicatione60e87cd-ba27-4148-a906-95e6cefff669
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublicationaeb8d351-f5d1-4768-9291-4528cc469907
relation.isAuthorOfPublication.latestForDiscoveryaeb8d351-f5d1-4768-9291-4528cc469907
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR
sigepi.autor.atividadeSANTOS, WILLIAM S.:12113:330:Npt_BR
sigepi.autor.atividadeSOARES, MARIA R.:14289:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27216.pdf
Tamanho:
716.97 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções