Biotribological behaviour evaluation of the ISO 5832-1 stainless steel for biomedical applications treated by optical fiber laser
| dc.contributor.author | PIERETTI, E.F. | |
| dc.contributor.author | COZZA, R.C. | |
| dc.contributor.author | NEVES, M.D.M. | |
| dc.coverage | Internacional | pt_BR |
| dc.creator.evento | INTERNATIONAL CONFERENCE ON BIOTRIBOLOGY, 3rd | pt_BR |
| dc.date.accessioned | 2017-07-04T16:55:12Z | |
| dc.date.available | 2017-07-04T16:55:12Z | |
| dc.date.evento | September 11-14, 2016 | pt_BR |
| dc.description.abstract | The present study evaluated the influence of an optical fiber laser surface treatment process on the tribological behaviour of the ISO 5832-1 austenitic stainless steel (SS) on the coefficient of friction and coefficient of wear in ball-cratering wear tests. For comparison reasons, surfaces non treated by laser were also evaluated. A phosphate buffer solution (PBS) was used as electrolyte. Samples of this biomaterial were treated by alternating the laser frequency in order to find out a condition that improves its tribological behaviour. Micro-abrasive wear tests were carried out with a ball of AISI 316L SS (diameter of 25.4 mm – 1”), used as counter-body, and abrasive slurries prepared with abrasive particles of Al2O3 and distilled water. The sample’s surfaces finishing were analyzed by optical and electronic (SEM-EDX) microscopy. The surface characterization showed microstructure modification due to the high temperatures involved in the laser process and the micro-abrasive wear results indicated that the tribological behaviour is influenced by the frequencies values used for the laser surface treatment. | pt_BR |
| dc.event.sigla | ICoBT | pt_BR |
| dc.identifier.citation | PIERETTI, E.F.; COZZA, R.C.; NEVES, M.D.M. Biotribological behaviour evaluation of the ISO 5832-1 stainless steel for biomedical applications treated by optical fiber laser. In: INTERNATIONAL CONFERENCE ON BIOTRIBOLOGY, 3rd, September 11-14, 2016, London, UK. <b>Abstract...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/27612. | |
| dc.identifier.orcid | https://orcid.org/0000-0002-1304-2117 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/27612 | |
| dc.local.evento | London, UK | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.title | Biotribological behaviour evaluation of the ISO 5832-1 stainless steel for biomedical applications treated by optical fiber laser | pt_BR |
| dc.type | Resumo de eventos científicos | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | EURICO FELIX PIERETTI | |
| ipen.autor | MAURICIO DAVID MARTINS DAS NEVES | |
| ipen.codigoautor | 9762 | |
| ipen.codigoautor | 19 | |
| ipen.contributor.ipenauthor | EURICO FELIX PIERETTI | |
| ipen.contributor.ipenauthor | MAURICIO DAVID MARTINS DAS NEVES | |
| ipen.date.recebimento | 17-07 | pt_BR |
| ipen.event.datapadronizada | 2016 | pt_BR |
| ipen.identifier.ipendoc | 23847 | pt_BR |
| ipen.notas.internas | Abstract | pt_BR |
| ipen.type.genre | Resumo | |
| relation.isAuthorOfPublication | 81bdc39e-9843-47fe-bbed-2ab1670d694a | |
| relation.isAuthorOfPublication | 99e4f42a-cdfa-4da0-a1fc-4788ca55471c | |
| relation.isAuthorOfPublication.latestForDiscovery | 81bdc39e-9843-47fe-bbed-2ab1670d694a | |
| sigepi.autor.atividade | PIERETTI, E.F.:9762:730:S | pt_BR |
| sigepi.autor.atividade | NEVES, M.D.M.:19:730:N | pt_BR |