Operational and Dosimetric Parameters of a 1.5 MeV electron beam irradiator in static and dynamic irradiation modes

Carregando...
Imagem de Miniatura

Data

Data de publicação

2024

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

É parte de

INTERNATIONAL SYMPOSIA ON RADIATION PHYSICS, 19th
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
Electron beam (EB) accelerators have been increasingly used in radiation processing applications. Most aim to achieve reproducible chemical and biological effects on the irradiated material to preserve or modify its characteristics with tight control of the absorbed dose (10-100 kGy). Accurate dosimetry, mainly carried out with standard reference alanine dosimeters and cellulose triacetate (CTA) films, is essential to ensure the reliability of the whole process [1]. However, variations in the electron energy, beam profiles, attainable dose rate, and conveyor speed also affect the dose absorbed in the irradiated product, requiring constant control and monitoring of these parameters. This task is accomplished with passive dosimeters in static irradiation mode following the international standard recommendations. To broaden the quality control of the irradiation process, it has been proposed to investigate the feasibility of using a homemade diode-based dosimetry system to measure the electron beam profiles and monitor variations in the radiation field in an industrial EB accelerator (DC 1500/25/04JOB188) [2]. This innovative system, when implemented, can provide real-time data, enabling immediate action and avoiding unexpected shutdowns, thereby enhancing the efficiency of the process. The dosimetry probe comprises a commercial diode (230 µm thick; 7.0 mm2 area), with the p+ front pad connected to the Keithley 6517B electrometer in the short-circuit mode. In dynamic mode, irradiations are carried out by sending the probe through the radiation field in the conveyor direction, varying speeds from 2 to 10 m/min. For reference, static measurements are also gathered with alanine pellets and cellulose triacetate (CTA) films. Regardless of the irradiation modes and the dosimeter types, the beam profiles and dose measurements are in good agreement, as shown in Fig.1. The data reproducibility remains to be investigated.

Como referenciar
GONÇALVES, J.A.C.; ASFORA, V.K.; KHOURY, H.J.; BUENO, C.C. Operational and Dosimetric Parameters of a 1.5 MeV electron beam irradiator in static and dynamic irradiation modes. In: PESSANHA, SOFIA (ed.); MANSO, MARTA (ed.). In: INTERNATIONAL SYMPOSIA ON RADIATION PHYSICS, 19th, September 1-5, 2024, Lisbon, Portugal. Abstract... Lisbon, Portugal: Universidade Nova de Lisboa - Faculdade de Ciências e Tecnologia, 2024. p. 160-160. Disponível em: https://repositorio.ipen.br/handle/123456789/48970. Acesso em: 09 Apr 2026.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento