Calibration of 90Sr /90Y Ophthalmic Brachytherapy Planar Sources Using Thermoluminescent Samples, a PMMA Phantom and Monte Carlo Simulation

dc.contributor.authorLITVAC, DANIEL
dc.contributor.authorCALDAS, LINDA
dc.coverageInternacional
dc.creator.eventoINTERNATIONAL CONFERENCE ON SOLID STATE DOSIMETRY, 20th
dc.date.accessioned2024-03-22T13:03:59Z
dc.date.available2024-03-22T13:03:59Z
dc.date.eventoSeptember 17-22, 2023
dc.description.abstractIn some parts of Brazil, 90Sr/90Y clinical applicators are still used for dermatological and ophthalmic treatments, despite the availability of new technologies worldwide and the use of Ru-106/Rh-106 Eye Applicator. This is because they are less expensive and easier to use. Calibration and periodic recalibration of these applicators to verify the absorbed dose rate are essential to ensure accuracy in clinical treatments. In this study, the thermoluminescent response of LiF pellets was evaluated to determine the reproducibility, linearity of response, and dose-response curves. Dose rates for some clinical applicators were determined using the LiF pellets, a PMMA phantom and the Monte Carlo method, following a project based on ISO 21439 (2009). This standard recommends the use of small detectors such as LiF for this type of calibration.
dc.event.siglaSSD20
dc.identifier.citationLITVAC, DANIEL; CALDAS, LINDA. Calibration of 90Sr /90Y Ophthalmic Brachytherapy Planar Sources Using Thermoluminescent Samples, a PMMA Phantom and Monte Carlo Simulation. In: INTERNATIONAL CONFERENCE ON SOLID STATE DOSIMETRY, 20th, September 17-22, 2023, Viareggio, Italy. <b>Abstract...</b> Disponível em: https://repositorio.ipen.br/handle/123456789/47972.
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/47972
dc.local.eventoViareggio, Italy
dc.rightsopenAccess
dc.titleCalibration of 90Sr /90Y Ophthalmic Brachytherapy Planar Sources Using Thermoluminescent Samples, a PMMA Phantom and Monte Carlo Simulation
dc.typeResumo de eventos científicos
dspace.entity.typePublication
ipen.autorDANIEL LITVAC
ipen.autorLINDA V. E. CALDAS
ipen.codigoautor14585
ipen.codigoautor1495
ipen.contributor.ipenauthorDANIEL LITVAC
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.event.datapadronizada2023
ipen.identifier.ipendoc30311
ipen.notas.internasAbstract
ipen.type.genreResumo
relation.isAuthorOfPublicationadb18c99-f219-46cb-a9d1-f852aed21453
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication.latestForDiscoveryadb18c99-f219-46cb-a9d1-f852aed21453
sigepi.autor.atividadeDANIEL LITVAC:14585:330:S
sigepi.autor.atividadeLINDA V. E. CALDAS:1495:330:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
30311.pdf
Tamanho:
48.99 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: