Analysis of the correction factor for the effect of the volumetric average using thermoluminescent dosimeters

dc.contributor.authorALMEIDA, S.B.
dc.contributor.authorCUNHA, A. P. V.
dc.contributor.authorSAMPAIO, C. C.
dc.contributor.authorCAMPOS, L.L.
dc.contributor.editorPESSANHA, SOFIA
dc.contributor.editorMANSO, MARTA
dc.coverageInternacional
dc.creator.eventoINTERNATIONAL SYMPOSIA ON RADIATION PHYSICS, 19th
dc.date.accessioned2025-12-22T18:27:44Z
dc.date.available2025-12-22T18:27:44Z
dc.date.eventoSeptember 1-5, 2024
dc.description.abstractAmong the dosimetry complexities of making use of small fields, the volume average correction factor is an essential factor for analysis. This factor is defined as the ratio between the dose absorbed in water at the reference point of the water phantom in the absence of the detector and the average dose absorbed over the sensitive volume of the detector (still in the absence of the detector). This occurs because the detector has a significant volume, having the potential to influence dosimetry depending on the region that has a high dose gradient or the size of the field that is intended to be measured (1,2,3). The objective of this work was to analyze the volumetric mean factor using TLDs (LiF:Mg,Ti; µLiF:Mg,Ti; CaSO4:Dy). To develop the effect of the volumetric average, some parameters are necessary, such as: the dimensions of the dosimeters and the profiles of the radiation beam. Due to the geometry of the dosimeters or detector used, it is necessary to take into account the weight function, w(x,y)(2). This parameter should approximate the dosimeter to a detector shape, such as: line, cylinder, cylinder with central electrode or a circular shape. In this work, the dosimeters were approximated to a detector with a circular shape like the diode, due to the face of the dosimeter facing the central beam of the linear accelerator. To be used the beam profiles were approximated to a Gaussian distribution that was obtained by the graphics program origin, in version 9.0. To calculate the volumetric average, a code developed by Cunha, 2019 using the Scilab software, version 6.0, was used. The fields analyzed were 2 x2 cm2 ; 1 x 1 cm2 and 0,5 x 0,5 cm2. The results obtained demonstrated that the µLiF was the dosimeter that had the least influence on the fields, showing an influence of only 2% in the 0.5 x 0.5 cm2 field, being considered the best detector for small field dosimetry. The LiF:Mg,Ti dosimeter showed a significant influence of 8% in the 1 x 1 cm2 field. CaSO4:Dy had an influence of 60% and is not recommended for use in fields smaller than 1 x 1 cm2.
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIDFAPESP: 18/05982-0
dc.description.sponsorshipIDCNPq: 426513/2018-5
dc.event.siglaISRP
dc.format.extent49-49
dc.identifier.citationALMEIDA, S.B.; CUNHA, A. P. V.; SAMPAIO, C. C.; CAMPOS, L.L. Analysis of the correction factor for the effect of the volumetric average using thermoluminescent dosimeters. In: PESSANHA, SOFIA (ed.); MANSO, MARTA (ed.). In: INTERNATIONAL SYMPOSIA ON RADIATION PHYSICS, 19th, September 1-5, 2024, Lisbon, Portugal. <b>Abstract...</b> Lisbon: Universidade Nova de Lisboa - Faculdade de Ciências e Tecnologia, Lisboa, 2024. p. 49-49. Disponível em: https://repositorio.ipen.br/handle/123456789/48965.
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/48965
dc.language.isoeng
dc.localLisbon, Portugal
dc.local.eventoLisbon, Portugal
dc.publisherUniversidade Nova de Lisboa - Faculdade de Ciências e Tecnologia
dc.rightsopenAccess
dc.titleAnalysis of the correction factor for the effect of the volumetric average using thermoluminescent dosimeters
dc.typeResumo de eventos científicos
dspace.entity.typePublication
ipen.autorSHIRLANE BARBOSA DE ALMEIDA
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.codigoautor14033
ipen.codigoautor1195
ipen.contributor.ipenauthorSHIRLANE BARBOSA DE ALMEIDA
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.event.datapadronizada2024
ipen.identifier.ipendoc31025
ipen.notas.internasAbstract
ipen.type.genreResumo
relation.isAuthorOfPublication2376fe21-10ec-46bd-b287-64478233f9ce
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication.latestForDiscoveryd4d34119-a6e6-4026-9a67-7b16d8b668da
sigepi.autor.atividadeSHIRLANE BARBOSA DE ALMEIDA:14033:330:S
sigepi.autor.atividadeLETICIA LUCENTE CAMPOS RODRIGUES:1195:330:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
31025.pdf
Tamanho:
123.93 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: