Pile-up correction for coincidence counting using a CAEN 1724 digitizer

dc.contributor.authorRIBEIRO JUNIOR, IBERE S.
dc.contributor.authorZAHN, GUILHERME S.
dc.contributor.authorGENEZINI, FREDERICO A.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2018-01-12T12:38:42Z
dc.date.available2018-01-12T12:38:42Z
dc.date.eventoOctober 22-27, 2017pt_BR
dc.description.abstractIn conventional gamma-ray spectrometry, the probability of pile-up effects is considered to be proportional to the dead-time, and is usually neglected for low dead-times (below 4-5%). In gamma-gamma coincidence spectrometry, though, while the dead time takes into account only events that are actually digitized, the pile-up effects are proportional to the actual gamma-ray detection rate in each detector, not only to the ones that trigger the coincidence gate. Thus, the pile-up corrections may not be so easy to assess as in single spectrometry systems. In this work, a system composed of two HPGe detectors coupled to a CAEN v1724 digitizer is studied. A 3kBq 60Co source was analyzed, both alone and in the presence of other radioactive sources (137Cs, 133Ba and 152Eu), and the resulting coincidence peak areas were compared to assess the effectiveness of two distinct corrections: a simple normalization by the live time of acquisition and the normalization by the count rate obtained using a pulse generator. The results obtained stress the need to use the pulse generator in this specific setup in order to get accurate results.pt_BR
dc.event.siglaINACpt_BR
dc.identifier.citationRIBEIRO JUNIOR, IBERE S.; ZAHN, GUILHERME S.; GENEZINI, FREDERICO A. Pile-up correction for coincidence counting using a CAEN 1724 digitizer. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. <b>Proceedings...</b> Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017. Disponível em: http://repositorio.ipen.br/handle/123456789/28303.
dc.identifier.orcidhttps://orcid.org/0000-0002-6318-6805
dc.identifier.orcidhttps://orcid.org/0000-0003-3237-8588
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28303
dc.localRio de Janeiro, RJpt_BR
dc.local.eventoBelo Horizonte, MGpt_BR
dc.publisherAssociação Brasileira de Energia Nuclearpt_BR
dc.rightsopenAccesspt_BR
dc.subjectbarium 133
dc.subjectcesium 137
dc.subjectcobalt 60
dc.subjectcorrections
dc.subjectdata acquisition
dc.subjectdead time
dc.subjectdigitizers
dc.subjecteuropium 152
dc.subjectgamma radiation
dc.subjecthigh-purity ge detectors
dc.subjectpulse pileup
dc.titlePile-up correction for coincidence counting using a CAEN 1724 digitizerpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorFREDERICO ANTONIO GENEZINI
ipen.autorGUILHERME SOARES ZAHN
ipen.autorIBERE SOUZA RIBEIRO JUNIOR
ipen.codigoautor2045
ipen.codigoautor950
ipen.codigoautor10189
ipen.contributor.ipenauthorFREDERICO ANTONIO GENEZINI
ipen.contributor.ipenauthorGUILHERME SOARES ZAHN
ipen.contributor.ipenauthorIBERE SOUZA RIBEIRO JUNIOR
ipen.date.recebimento18-01pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc24138pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication0c41d307-45a9-47c4-8281-5aa9ed46e6a4
relation.isAuthorOfPublicationde99ffee-d830-4bea-aeeb-e8f3ccc34921
relation.isAuthorOfPublicationa978a384-2cd4-4fe3-8a0e-454eca29efe1
relation.isAuthorOfPublication.latestForDiscoverya978a384-2cd4-4fe3-8a0e-454eca29efe1
sigepi.autor.atividadeRIBEIRO JUNIOR, IBERE S.:10189:310:Spt_BR
sigepi.autor.atividadeZAHN, GUILHERME S.:950:310:Npt_BR
sigepi.autor.atividadeGENEZINI, FREDERICO A.:2045:310:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24138.pdf
Tamanho:
518.5 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções