Comparison of microleakage and thermographic evaluation of root canal irradiated by Er:YAG and Nd:YAG lasers

dc.contributor.authorGOYA, C.pt_BR
dc.contributor.authorZEZELL, D.M.pt_BR
dc.contributor.authorMATSUMOTO, K.pt_BR
dc.contributor.authorEDUARDO, C.P.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoCONGRESS OF THE GERMAN SOCIETY FOR LASER DENTISTRY DGL, 10thpt_BR
dc.date.accessioned2014-11-19T11:30:14Zpt_BR
dc.date.accessioned2014-11-19T14:10:12Zpt_BR
dc.date.accessioned2015-04-01T12:41:17Z
dc.date.available2014-11-19T11:30:14Zpt_BR
dc.date.available2014-11-19T14:10:12Zpt_BR
dc.date.available2015-04-01T12:41:17Z
dc.date.eventoMay 17-20, 2001pt_BR
dc.description.abstractPurpose: This study was carried out to compare the apical leakage after Er:YAG and Nd:YAG lasers irradiation with both techniques: helicoidal and vertical irradiations and to evaluate temperature changes at root surface. Materials and Methods: The extracted human teeth were instrumented then treated by Nd:YAG (1,064nm) and Er:YAG (2,940nm) lasers with two techniques: helicoidal and vertical irradiations. The Nd:YAG laser parameters was: 100mJ, 15Hz, 1.5W, and for the Er:YAG laser was 160mJ, 10Hz. SEM, and stereoscopy evaluations were performed. Results: The apical leakage was less in the teeth treated by lasers, and the irradiation with the Nd:YAG laser after Er:YAG laser decreased the apical leakage. The thermographic study found that temperature rise was less than 6°C. Conclusion: The results suggest the usefulness of Nd:YAG laser intracanal irradia
dc.format.extent4pt_BR
dc.identifier.citationGOYA, C.; ZEZELL, D.M.; MATSUMOTO, K.; EDUARDO, C.P. Comparison of microleakage and thermographic evaluation of root canal irradiated by Er:YAG and Nd:YAG lasers. In: CONGRESS OF THE GERMAN SOCIETY FOR LASER DENTISTRY DGL, 10th, May 17-20, 2001, Vienna, Austria. <b>Abstracts...</b> p. 4. Disponível em: http://repositorio.ipen.br/handle/123456789/20782.
dc.identifier.orcidhttps://orcid.org/0000-0001-7404-9606
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/20782pt_BR
dc.local.eventoVienna, Austriapt_BR
dc.rightsopenAccess
dc.subjectlaserspt_BR
dc.subjecterbiumpt_BR
dc.subjectneodymium laserspt_BR
dc.subjectteethpt_BR
dc.subjectirradiationpt_BR
dc.subjectleakspt_BR
dc.subjecttemperature measurementpt_BR
dc.titleComparison of microleakage and thermographic evaluation of root canal irradiated by Er:YAG and Nd:YAG laserspt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorDENISE MARIA ZEZELL
ipen.codigoautor693
ipen.contributor.ipenauthorDENISE MARIA ZEZELL
ipen.date.recebimento02-06pt_BR
ipen.event.datapadronizada2001pt_BR
ipen.identifier.ipendoc08044pt_BR
ipen.notas.internasAbstractspt_BR
ipen.type.genreResumo
relation.isAuthorOfPublicationa565f8ad-3432-4891-98c0-a587f497db21
relation.isAuthorOfPublication.latestForDiscoverya565f8ad-3432-4891-98c0-a587f497db21
sigepi.autor.atividadeZEZELL, D.M.:693:31:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
08044.pdf
Tamanho:
1.15 MB
Formato:
Adobe Portable Document Format