Rapid and accurate assessment of the activity measurements in Brazilian hospitals and clinics

dc.contributor.authorOLIVEIRA, A.E. de
dc.contributor.authorIWAHARA, A.
dc.contributor.authorCRUZ, P.A.L. da
dc.contributor.authorSILVA, C.J. da
dc.contributor.authorARAUJO, E.B. de
dc.contributor.authorMENGATTI, J.
dc.contributor.authorSILVA, R.L. da
dc.contributor.authorTRINDADE, O.L.
dc.coverageInternacionalpt_BR
dc.date.accessioned2018-04-23T10:40:49Z
dc.date.available2018-04-23T10:40:49Z
dc.date.issued2018pt_BR
dc.description.abstractTraceability in Nuclear Medicine Service (NMS) measurements was checked by the Institute of Radioprotection and Dosimetry (IRD) through the Institute of Energy and Nuclear Research (IPEN). In 2016, IRD ran an inter comparison program and invited Brazilian NMS authorized to administer I-131 to patients. Sources of I-131 were distributed to 33 NMSs. Three other sources from the same solution were sent to IRD, after measurement at IPEN. These sources were calibrated in the IRD reference system. A correction factor of 1.013 was obtained. Ninety percent of the NMS comparisons results are within +/- 10% of the National Laboratory of Metrology of Ionizing Radiation (LNMRI) value, the Brazilian legal requirement.pt_BR
dc.format.extent64-67pt_BR
dc.identifier.citationOLIVEIRA, A.E. de; IWAHARA, A.; CRUZ, P.A.L. da; SILVA, C.J. da; ARAUJO, E.B. de; MENGATTI, J.; SILVA, R.L. da; TRINDADE, O.L. Rapid and accurate assessment of the activity measurements in Brazilian hospitals and clinics. <b>Applied Radiation and Isotopes</b>, v. 134, n. SI, p. 64-67, 2018. DOI: <a href="https://dx.doi.org/10.1016/j.apradiso.2017.07.065">10.1016/j.apradiso.2017.07.065</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/28863.
dc.identifier.doi10.1016/j.apradiso.2017.07.065pt_BR
dc.identifier.fasciculoSIpt_BR
dc.identifier.issn0969-8043pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-0456-5589
dc.identifier.percentilfi38.22en
dc.identifier.percentilfiCiteScore53.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28863
dc.identifier.vol134pt_BR
dc.relation.ispartofApplied Radiation and Isotopespt_BR
dc.rightsopenAccesspt_BR
dc.source21st International Conference on Radionuclide Metrology and its Applications (ICRM). Buenos Aires, ARGENTINA MAY 15-19, 2017pt_BR
dc.subjectquality control
dc.subjectiodine 131
dc.subjectnuclear medicine
dc.subjecthealth services
dc.subjecthospitals
dc.subjectradioisotopes
dc.subjectbrazil
dc.titleRapid and accurate assessment of the activity measurements in Brazilian hospitals and clinicspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorJAIR MENGATTI
ipen.autorELAINE BORTOLETI DE ARAUJO
ipen.codigoautor1498
ipen.codigoautor664
ipen.contributor.ipenauthorJAIR MENGATTI
ipen.contributor.ipenauthorELAINE BORTOLETI DE ARAUJO
ipen.date.recebimento18-04pt_BR
ipen.identifier.fi1.343pt_BR
ipen.identifier.fiCiteScore2.1
ipen.identifier.ipendoc24365pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.range.percentilfi25.00 - 49.99
ipen.type.genreArtigo
relation.isAuthorOfPublication4722b83e-1d23-488f-b497-6a72d3048679
relation.isAuthorOfPublicationca74886d-6974-47a8-9308-c4cc39bb6e35
relation.isAuthorOfPublication.latestForDiscoveryca74886d-6974-47a8-9308-c4cc39bb6e35
sigepi.autor.atividadeARAUJO, E.B. DE:664:110:Npt_BR
sigepi.autor.atividadeMENGATTI, J.:1498:110:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24365.pdf
Tamanho:
161.34 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções