Evaluation of dosimetric parameters for diagnosis X ray beams with radiation tolerant silicon diodes

dc.contributor.authorPEREIRA, L.N.pt_BR
dc.contributor.authorGONCALVES, J.A.C.pt_BR
dc.contributor.authorBIZETTO, C.pt_BR
dc.contributor.authorPOTIENS, M.P.A.pt_BR
dc.contributor.authorVIVOLO, V.pt_BR
dc.contributor.authorBUENO, C.C.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONFERENCE ON SOLID STATE DOSIMETRY, 17thpt_BR
dc.date.accessioned2014-11-19T10:57:13Zpt_BR
dc.date.accessioned2014-11-19T14:13:23Zpt_BR
dc.date.accessioned2015-04-01T12:41:12Z
dc.date.available2014-11-19T10:57:13Zpt_BR
dc.date.available2014-11-19T14:13:23Zpt_BR
dc.date.available2015-04-01T12:41:12Z
dc.date.evento22-27 de setembro, 2013pt_BR
dc.event.siglaSSD17pt_BR
dc.identifier.citationPEREIRA, L.N.; GONCALVES, J.A.C.; BIZETTO, C.; POTIENS, M.P.A.; VIVOLO, V.; BUENO, C.C. Evaluation of dosimetric parameters for diagnosis X ray beams with radiation tolerant silicon diodes. In: INTERNATIONAL CONFERENCE ON SOLID STATE DOSIMETRY, 17th, 22-27 de setembro, 2013, Recife, PE. <b>Abstract...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/20282.
dc.identifier.orcidhttps://orcid.org/0000-0001-7881-7254
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.orcidhttps://orcid.org/0000-0002-8940-9544
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/20282pt_BR
dc.local.eventoRecife, PEpt_BR
dc.rightsopenAccesspt_BR
dc.subjectdiagnostic techniquespt_BR
dc.subjectradiologypt_BR
dc.subjectdosimetrypt_BR
dc.subjectsilicon diodespt_BR
dc.subjectepitaxypt_BR
dc.subjectcalibrationpt_BR
dc.subjectelectron beamspt_BR
dc.subjectdose ratespt_BR
dc.titleEvaluation of dosimetric parameters for diagnosis X ray beams with radiation tolerant silicon diodespt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorCARMEN CECILIA BUENO TOBIAS
ipen.autorVITOR VIVOLO
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorJOSEMARY ANGELICA CORREA GONCALVES
ipen.codigoautor1592
ipen.codigoautor406
ipen.codigoautor346
ipen.codigoautor924
ipen.contributor.ipenauthorCARMEN CECILIA BUENO TOBIAS
ipen.contributor.ipenauthorVITOR VIVOLO
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorJOSEMARY ANGELICA CORREA GONCALVES
ipen.date.recebimento14-01pt_BR
ipen.event.datapadronizada2013pt_BR
ipen.identifier.ipendoc19768pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublicationfa74399b-83a0-4f46-91e0-da469104d3f6
relation.isAuthorOfPublication6875184b-48f2-43e7-b6de-e676ee5db15a
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication76fdc4d1-7624-4332-a9d0-f06826000679
relation.isAuthorOfPublication.latestForDiscovery76fdc4d1-7624-4332-a9d0-f06826000679
sigepi.autor.atividadePEREIRA, L.N.:-1:-1:Spt_BR
sigepi.autor.atividadeGONÇALVES, J.A.C.:924:240:Npt_BR
sigepi.autor.atividadeBIZETTO, C.:-1:-1:Npt_BR
sigepi.autor.atividadePOTIENS, M.P.A.:346:330:Npt_BR
sigepi.autor.atividadeVIVOLO, V.:406:330:Npt_BR
sigepi.autor.atividadeBUENO, C.C.:1592:240:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
19768.pdf
Tamanho:
692.44 KB
Formato:
Adobe Portable Document Format