Activimeter response behaviour analysis related to well depth

dc.contributor.authorKUAHARA, LILIANpt_BR
dc.contributor.authorCORREA, EDUARDOpt_BR
dc.contributor.authorPOTIENS, MARIA da P.pt_BR
dc.contributor.editorCLEMENT, CHRISTOPHERpt_BR
dc.contributor.editorVALENTIN, JACKpt_BR
dc.contributor.editorOGINO, HARUYUKIpt_BR
dc.contributor.editorFOOTE, DEVONpt_BR
dc.contributor.editorREYJAL, JULIEpt_BR
dc.contributor.editorOMAR-NAZIR, LAILApt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 14thpt_BR
dc.date.accessioned2020-06-09T18:48:27Z
dc.date.available2020-06-09T18:48:27Z
dc.date.eventoMay 9-13, 2016pt_BR
dc.description.abstractThe activimeter, instrument used to radionuclide activity measure, consist primarily of a well type ionization chamber coupled to a special electronic device. Its response, after calibration, is shown in units of the activity quantity (Becquerel or Curie). It also has a special holder designed to accommodate all kinds of syringes and vials containing the radiopharmaceuticals. Many factors influence the response of an activimeter such as the volume of the sample, its position inside the activimeter well and the geometry of the vials. The idea of this study is to find the better position inside the well to get the best activity values, positioning the holder in different profundity, simulating a clinical procedure. The reference activimeter used was the Secondary Standard NPL-CRC radionuclide calibrator, traceable to the National Physical Laboratory (NPL), England, taking as reference the depth of 400 mm. Two other activimeters were tested: Capintec, CRC-15BT model with the depth of 170 mm and one CRC-25R model with depth of 257 mm. They all belong to the Instrument Calibration Laboratory of IPEN, São Paulo, Brazil. The measurements were made using three radioactive check sources: Co-57, Ba-133 and Cs-137. Sources readings were taken at various depths inside the ionization chamber well. The results shown maximum variation of 14.28% for Co-57, 11.27% to Ba-133 and 8.8% to Cs-137. All measurements were compared with those values found for the reference depth in each activimeter. The variation found show the necessity of include this kind of determination in all quality control programs that are applied to an activimeter used by a Nuclear Medicine Service.pt_BR
dc.event.siglaIRPApt_BR
dc.format.extent756-756pt_BR
dc.identifier.citationKUAHARA, LILIAN; CORREA, EDUARDO; POTIENS, MARIA da P. Activimeter response behaviour analysis related to well depth. In: CLEMENT, CHRISTOPHER (ed.); VALENTIN, JACK (ed.); OGINO, HARUYUKI (ed.); FOOTE, DEVON (ed.); REYJAL, JULIE (ed.); OMAR-NAZIR, LAILA (ed.). In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 14th, May 9-13, 2016, Cape Town, South Africa. <b>Abstract...</b> p. 756-756. Disponível em: http://repositorio.ipen.br/handle/123456789/31269.
dc.identifier.orcid0000-0002-4049-6720pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/31269
dc.local.eventoCape Town, South Africapt_BR
dc.publisherThe International Radiation Protection Associationpt_BR
dc.rightsopenAccesspt_BR
dc.titleActivimeter response behaviour analysis related to well depthpt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorEDUARDO DE LIMA CORREA
ipen.autorLILIAN TOSHIE KUAHARA
ipen.codigoautor346
ipen.codigoautor7498
ipen.codigoautor10859
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorEDUARDO DE LIMA CORREA
ipen.contributor.ipenauthorLILIAN TOSHIE KUAHARA
ipen.date.recebimento20-06
ipen.event.datapadronizada2016pt_BR
ipen.identifier.ipendoc27011pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication1f00087b-0c1b-413b-8464-2842b24a7328
relation.isAuthorOfPublication44381d85-6097-40f4-b9a3-9e991b7bebe5
relation.isAuthorOfPublication.latestForDiscovery44381d85-6097-40f4-b9a3-9e991b7bebe5
sigepi.autor.atividadePOTIENS, MARIA da P.:346:330:Npt_BR
sigepi.autor.atividadeCORREA, EDUARDO:7498:310:Npt_BR
sigepi.autor.atividadeKUAHARA, LILIAN:10859:-1:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27011.pdf
Tamanho:
230.59 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: