Neutron-induced electron radiography
| dc.contributor.author | PUGLIESI, R. | pt_BR |
| dc.contributor.author | ANDRADE, M.L.G. | pt_BR |
| dc.contributor.author | PEREIRA, M.A.S. | pt_BR |
| dc.contributor.author | PUGLIESI, F. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2014-07-15T13:49:31Z | pt_BR |
| dc.date.accessioned | 2014-07-30T11:50:59Z | |
| dc.date.available | 2014-07-15T13:49:31Z | pt_BR |
| dc.date.available | 2014-07-30T11:50:59Z | |
| dc.date.issued | 2005 | pt_BR |
| dc.description.abstract | In the present work, a new radiographic methodology which makes use of conventional X-ray films and low-energy electrons as penetrating radiation, to inspect low-thickness samples, has been investigated. The radiographic characteristics for the ‘‘electron beam–film’’ set, regarding its sensitivity to discern thickness changes of materials, as well as the spatial resolution achieved in the image have been determined. Some radiographs are presented and demonstrate the method’s potential to inspect thin samples. | |
| dc.format.extent | 81-86 | pt_BR |
| dc.identifier.citation | PUGLIESI, R.; ANDRADE, M.L.G.; PEREIRA, M.A.S.; PUGLIESI, F. Neutron-induced electron radiography. <b>Nuclear Instruments and Methods in Physics Research</b>, v. 542, n. 1-3, p. 81-86, 2005. Section A. DOI: <a href="https://dx.doi.org/10.1016/j.nima.2005.01.015">10.1016/j.nima.2005.01.015</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5562. | |
| dc.identifier.doi | 10.1016/j.nima.2005.01.015 | |
| dc.identifier.fasciculo | 1-3 | pt_BR |
| dc.identifier.issn | 0168-9002 | pt_BR |
| dc.identifier.suplemento | Section A | pt_BR |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/5562 | pt_BR |
| dc.identifier.vol | 542 | pt_BR |
| dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research | pt_BR |
| dc.rights | openAccess | en |
| dc.source | Apresentado tambem em: International Topical Meeting on Neutron Radiography, Garcing, Germany, Jul. 26-30, 2004 | pt_BR |
| dc.subject | electron beams | pt_BR |
| dc.subject | electrons | pt_BR |
| dc.subject | images | pt_BR |
| dc.subject | neutrons | pt_BR |
| dc.subject | sensitivity | pt_BR |
| dc.subject | spatial resolution | pt_BR |
| dc.subject | thickness | pt_BR |
| dc.subject | thin films | pt_BR |
| dc.subject | layers | pt_BR |
| dc.subject | x radiation | pt_BR |
| dc.title | Neutron-induced electron radiography | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | FABIO PUGLIESI | |
| ipen.autor | MARCOS LEANDRO GARCIA ANDRADE | |
| ipen.autor | REYNALDO PUGLIESI | |
| ipen.autor | MARCO ANTONIO STANOJEV PEREIRA | |
| ipen.codigoautor | 2238 | |
| ipen.codigoautor | 2610 | |
| ipen.codigoautor | 1391 | |
| ipen.codigoautor | 2133 | |
| ipen.contributor.ipenauthor | FABIO PUGLIESI | |
| ipen.contributor.ipenauthor | MARCOS LEANDRO GARCIA ANDRADE | |
| ipen.contributor.ipenauthor | REYNALDO PUGLIESI | |
| ipen.contributor.ipenauthor | MARCO ANTONIO STANOJEV PEREIRA | |
| ipen.date.recebimento | 66-66 | pt_BR |
| ipen.identifier.fi | 1.224 | pt_BR |
| ipen.identifier.ipendoc | 10590 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.range.fi | 0.001 - 1.499 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | bee2d18b-6055-4372-96a1-e5d863265ee2 | |
| relation.isAuthorOfPublication | 6241dbf9-e651-4c16-93b6-c28032efb723 | |
| relation.isAuthorOfPublication | 7c9b511e-1210-4f64-8a4c-c3546c3f7876 | |
| relation.isAuthorOfPublication | 0192edfe-c986-47f3-a384-7dd4093ff566 | |
| relation.isAuthorOfPublication.latestForDiscovery | 7c9b511e-1210-4f64-8a4c-c3546c3f7876 | |
| sigepi.autor.atividade | PUGLIESI, R.:1391:6:S | pt_BR |
| sigepi.autor.atividade | ANDRADE, M.L.G.:2610:6:N | pt_BR |
| sigepi.autor.atividade | PEREIRA, M.A.S.:2133:-1:N | pt_BR |
| sigepi.autor.atividade | PUGLIESI, F.:2238:-1:N | pt_BR |
Pacote Original
1 - 1 de 1