GEANT4 simulation of the angular dependence of TLD-based monitor response

dc.contributor.authorGUIMARAES, C.C.pt_BR
dc.contributor.authorMORALLES, M.pt_BR
dc.contributor.authorOKUNO, E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:44:57Zpt_BR
dc.date.accessioned2014-07-30T11:48:11Z
dc.date.available2014-07-15T13:44:57Zpt_BR
dc.date.available2014-07-30T11:48:11Z
dc.date.issued2007pt_BR
dc.description.abstractIn this work, the response of thermoluminescent (TL) monitors to X-ray beams impinging on them at different angles was investigated and compared with results of simulations performed with the GEANT4 radiation transport toolkit. Each monitor used contains four TL detectors (TLD): two CaF2 pellets and two TLD-100 (one of each type within lead filter and the other without filter). Monitors were irradiated free-in-air with X-ray beams of the narrow and wide spectrum with effective energy of 61 and 130 keV and angles of incidence of 0°, 30°, 45°, and 60°. Curves of TL response relative to air kerma as a function of photon effective energy for each detector, with and without filter, are used to correct the energetic dependence of TL response. Such curves were also obtained from the data of radiation energy stored in the TLDs provided by the simulations. The attenuation increases with the increase of the incidence angle, since the thickness of lead filter traversed by the beam also enlarges. As the monitor calibration is usually performed with the beams impinging the monitor at 0°, changes in the attenuation become a source of error in the energy determination and consequently in the value of dose equivalent obtained with this monitor. The changes in attenuation observed in experiments were corroborated by the Monte Carlo simulations.
dc.format.extent514-517pt_BR
dc.identifier.citationGUIMARAES, C.C.; MORALLES, M.; OKUNO, E. GEANT4 simulation of the angular dependence of TLD-based monitor response. <b>Nuclear Instruments and Methods in Physics Research</b>, v. 580, p. 514-517, 2007. Section A. DOI: <a href="https://dx.doi.org/10.1016/j.nima.2007.05.218">10.1016/j.nima.2007.05.218</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5164.
dc.identifier.doi10.1016/j.nima.2007.05.218
dc.identifier.issn0168-9002pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-2664-5531
dc.identifier.suplementoSection Apt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5164pt_BR
dc.identifier.vol580pt_BR
dc.relation.ispartofNuclear Instruments and Methods in Physics Researchpt_BR
dc.rightsopenAccessen
dc.subjectthermoluminescencept_BR
dc.subjectthermoluminescent dosimetrypt_BR
dc.subjectradiation monitorspt_BR
dc.subjectmonte carlo methodpt_BR
dc.subjectsimulationpt_BR
dc.titleGEANT4 simulation of the angular dependence of TLD-based monitor responsept_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMAURICIO MORALLES
ipen.codigoautor923
ipen.contributor.ipenauthorMAURICIO MORALLES
ipen.date.recebimento08-07pt_BR
ipen.identifier.fi1.114pt_BR
ipen.identifier.ipendoc12734pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublicationdc9e7d8e-c880-41f7-971e-b300272b6750
relation.isAuthorOfPublication.latestForDiscoverydc9e7d8e-c880-41f7-971e-b300272b6750
sigepi.autor.atividadeMORALLES, M.:923:6:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
12734.pdf
Tamanho:
151.19 KB
Formato:
Adobe Portable Document Format

Coleções