Development of an additional filtration system by 3D printing for the implementation of new X-ray beam qualities used in diagnostic radiology

Carregando...
Imagem de Miniatura

Data

Data de publicação

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

Brazilian Journal of Radiation Sciences
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
The Calibration Laboratory (LCI) of the Nuclear and Energy Research Institute (IPEN-CNEN) offers calibration services for radiation measurements instruments used in radiation protection, diagnostic radiology and radiotherapy. LCI produces radiation qualities and irradiation conditions which are in accordance with the national and international standard requirements. In order to establish the recommended radiation qualities for diagnostic radiology, X-ray beams generated in laboratory are modified for the irradiation conditions found in equipment routinely used in healthcare services. In this work, a new additional filtration system was developed to be adapted to the existing filter system at LCI. The new filter support can be coupled to the PTW Bench Control installed at the LCI X-ray system. Using a FDM 3D printer, a support model and a set of drawers were developed for the placement of additional filters. The models were also developed to fit each specific drawer of each filter to be used in the laboratory routine, coupled to the specific sensors that fit the spaces of the support part. Additionally, a microcontroller based on Arduino, micro switches, low- and high-level programming, allow checking of drawer status and integration of information with the laboratory control system. The system allows the recognition of the filter inserted in the drawer from sensors attached to the support. Tests were carried out to verify the usability of the system in the routine, adding Ag (silver) and Cu (copper) filters, for the characterization of attenuated radiation beams of interest in diagnostic radiology.

Como referenciar
ALMEIDA JUNIOR, J.N.; POTIENS, M.P.A.; RODRIGUES JUNIOR, O. Development of an additional filtration system by 3D printing for the implementation of new X-ray beam qualities used in diagnostic radiology. Brazilian Journal of Radiation Sciences, v. 10, n. 3B, p. 1-7, 2022. DOI: 10.15392/2319-0612.2022.1992. Disponível em: http://repositorio.ipen.br/handle/123456789/33497. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento

Coleções