Pile-up correction for coincidence counting using a CAEN 1724 digitizer

dc.contributor.authorZAHN, GUILHERME S.pt_BR
dc.contributor.authorRIBEIRO JUNIOR, IBERE S.pt_BR
dc.contributor.authorGENEZINI, FREDERICO A.pt_BR
dc.coverageNacionalpt_BR
dc.date.accessioned2019-08-05T11:36:49Z
dc.date.available2019-08-05T11:36:49Z
dc.date.issued2019pt_BR
dc.description.abstractIn conventional gamma-ray spectrometry, the probability of pile-up effects is considered to be proportional to the dead-time, and is usually neglected for low dead-times (below 4-5%). In gamma-gamma coincidence spectrometry, though, while the dead time takes into account only events that are actually digitized, the pile-up effects are proportional to the actual gamma-ray detection rate in each detector, not only to the ones that trigger the coincidence gate. Thus, the pile-up corrections may not be so easy to assess as in single spectrometry systems. In this work, a system composed of two HPGe detectors coupled to a CAEN v1724 digitizer is studied. A 3kBq 60Co source was analyzed, both alone and in the presence of other radioactive sources (137Cs, 133Ba and 152Eu), and the resulting coincidence peak areas were compared to assess the effectiveness of two distinct corrections: a simple normalization by the live time of acquisition and the normalization by the count rate obtained using a pulse generator. The results obtained stress the need to use the pulse generator in this specific setup in order to get accurate results.pt_BR
dc.format.extent1-10pt_BR
dc.identifier.citationZAHN, GUILHERME S.; RIBEIRO JUNIOR, IBERE S.; GENEZINI, FREDERICO A. Pile-up correction for coincidence counting using a CAEN 1724 digitizer. <b>Brazilian Journal of Radiation Sciences</b>, v. 7, n. 2A, p. 1-10, 2019. DOI: <a href="https://dx.doi.org/10.15392/bjrs.v7i2A.578">10.15392/bjrs.v7i2A.578</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/30021.
dc.identifier.doi10.15392/bjrs.v7i2A.578pt_BR
dc.identifier.fasciculo2Apt_BR
dc.identifier.issn2319-0612pt_BR
dc.identifier.orcid0000-0002-6318-6805pt_BR
dc.identifier.orcid0000-0003-3237-8588pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-6318-6805
dc.identifier.orcidhttps://orcid.org/0000-0003-3237-8588
dc.identifier.percentilfiSem Percentilpt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30021
dc.identifier.vol7pt_BR
dc.relation.ispartofBrazilian Journal of Radiation Sciencespt_BR
dc.rightsopenAccesspt_BR
dc.sourceThe Meeting on Nuclear Applications (ENAN), 13th, 22-27 de outubro, 2017, Belo Horizonte, MGpt_BR
dc.subjectcorrections
dc.subjectdigitizers
dc.subjectdata acquisition
dc.subjectdead time
dc.subjectgamma radiation
dc.subjectbarium 133
dc.subjecteuropium 152
dc.subjectcesium 137
dc.subjectcobalt 60
dc.subjectdata acquisition
dc.subjecthigh-purity ge detectors
dc.subjectpulse pileup
dc.titlePile-up correction for coincidence counting using a CAEN 1724 digitizerpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorIBERE SOUZA RIBEIRO JUNIOR
ipen.autorFREDERICO ANTONIO GENEZINI
ipen.autorGUILHERME SOARES ZAHN
ipen.codigoautor10189
ipen.codigoautor2045
ipen.codigoautor950
ipen.contributor.ipenauthorIBERE SOUZA RIBEIRO JUNIOR
ipen.contributor.ipenauthorFREDERICO ANTONIO GENEZINI
ipen.contributor.ipenauthorGUILHERME SOARES ZAHN
ipen.date.recebimento19-08
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc25813pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationa978a384-2cd4-4fe3-8a0e-454eca29efe1
relation.isAuthorOfPublication0c41d307-45a9-47c4-8281-5aa9ed46e6a4
relation.isAuthorOfPublicationde99ffee-d830-4bea-aeeb-e8f3ccc34921
relation.isAuthorOfPublication.latestForDiscoveryde99ffee-d830-4bea-aeeb-e8f3ccc34921
sigepi.autor.atividadeGENEZINI, FREDERICO A.:2045:310:Npt_BR
sigepi.autor.atividadeRIBEIRO JUNIOR, IBERE S.:10189:310:Npt_BR
sigepi.autor.atividadeZAHN, GUILHERME S.:950:310:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25813.pdf
Tamanho:
557.05 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções