Methodology for monitoring the residual activity in silicon rods irradiated with thermal neutrons

dc.contributor.authorDIAS, M.S.pt_BR
dc.contributor.authorSEBASTIAO, J.R.pt_BR
dc.contributor.authorKOSKINAS, M.F.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-31T11:33:15Zpt_BR
dc.date.accessioned2014-07-31T11:56:14Z
dc.date.available2014-07-31T11:33:15Zpt_BR
dc.date.available2014-07-31T11:56:14Z
dc.date.issued2002pt_BR
dc.description.abstractA calibrated detection system developed for monitoring the residual activity in silicon rods irradiated for neutron transmutation doping is described. This residual activity is mainly due to 31Si and 32P, produced by thermal neutron capture reactions. The set-up consists of a scanning device, developed for positioning the rods, coupled to a GM detector for measuring b-rays coming from the rod. The set-up has been calibrated using a 32P aqueous solution standardised in a 4pb gas-flow proportional counter system. The validity of the experimental procedure has been checked by Monte Carlo calculations. An additional check has been made by measuring the residual activity of a silicon rod irradiated in a well-known neutron fluence and the formalism used for calculating the activity on the basis of irradiation parameters is given. The results are compared to the radiological limit imposed by IAEA regulations in order to consider the material as exempt before it could be released for industrial applications.
dc.format.extent801-804pt_BR
dc.identifier.citationDIAS, M.S.; SEBASTIAO, J.R.; KOSKINAS, M.F. Methodology for monitoring the residual activity in silicon rods irradiated with thermal neutrons. <b>Applied Radiation and Isotopes</b>, v. 57, n. 6, p. 801-804, 2002. DOI: <a href="https://dx.doi.org/10.1016/S0969-8043(02)00195-1">10.1016/S0969-8043(02)00195-1</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/7379.
dc.identifier.doi10.1016/S0969-8043(02)00195-1
dc.identifier.fasciculo6pt_BR
dc.identifier.issn0969-8043pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-8407-9833
dc.identifier.orcidhttps://orcid.org/0000-0003-2478-5757
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/7379pt_BR
dc.identifier.vol57pt_BR
dc.relation.ispartofApplied Radiation and Isotopespt_BR
dc.rightsopenAccessen
dc.subjectradiation detectionpt_BR
dc.subjectcalibrationpt_BR
dc.subjectsilicon 31pt_BR
dc.subjectphosphorus 32pt_BR
dc.subjectgeiger-mueller counterspt_BR
dc.subjectbeta detectionpt_BR
dc.subjectradioactivitypt_BR
dc.subjectradiation monitoringpt_BR
dc.subjectsiliconpt_BR
dc.subjectrodspt_BR
dc.subjectmonte carlo methodpt_BR
dc.titleMethodology for monitoring the residual activity in silicon rods irradiated with thermal neutronspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMARINA FALLONE KOSKINAS
ipen.autorMAURO DA SILVA DIAS
ipen.autorJOSE RICARDO SEBASTIAO
ipen.codigoautor1387
ipen.codigoautor1292
ipen.codigoautor12428
ipen.contributor.ipenauthorMARINA FALLONE KOSKINAS
ipen.contributor.ipenauthorMAURO DA SILVA DIAS
ipen.contributor.ipenauthorJOSE RICARDO SEBASTIAO
ipen.date.recebimento03-12pt_BR
ipen.identifier.fi0.768pt_BR
ipen.identifier.ipendoc09099pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication420a8816-64da-4bb8-a1c4-5b8b638033b1
relation.isAuthorOfPublication58653850-db59-4051-aa72-5c32a5f6670e
relation.isAuthorOfPublication77216ef1-7700-4627-8c06-e6f57b2b6023
relation.isAuthorOfPublication.latestForDiscovery58653850-db59-4051-aa72-5c32a5f6670e
sigepi.autor.atividadeDIAS, M.S.:1292:6:Spt_BR
sigepi.autor.atividadeSEBASTIAO, J.R.:12428:-1:Npt_BR
sigepi.autor.atividadeKOSKINAS, M.F.:1387:6:Npt_BR