Characteristics of Pb2+ doped CsI matriz under gamma and neutron excitations

dc.contributor.authorPEREIRA, MARIA da C.C.
dc.contributor.authorMADI FILHO, TUFIC
dc.contributor.authorBERRETTA, JOSE R.
dc.contributor.authorTOMAZ, LUCAS F.
dc.contributor.authorPINTO, MARLENE C.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2018-01-12T12:16:51Z
dc.date.available2018-01-12T12:16:51Z
dc.date.eventoOctober 22-27, 2017pt_BR
dc.description.abstractIn recent years, there has been an increasing interest in finding new fast scintillating material or improve the characteristics of known scintillators for the demand of high energy physics, industrial and nuclear medical applications. Ions divalent lead Pb2+ built in some crystal structures are efficient emission centers and their applications in scintillators was and still is the reason of an intensive study of emission properties of different compounds containing these ions. The aggregation of impurities in CsI is poorly studied. The problem of impurity aggregation in CsI is of interest from point of view of the luminescent properties modification of this scintillation material. In this context, the crystals of Pb2+ doped CsI matrix were grown by the vertical Bridgman technique and subjected to annealing in vacuum of 10-6 mbar and continuous temperatura of 350°C, for 24 hours, and then they were employed. To evaluate the response of the CsI:Pb scintillator crystal to gamma radiation, radioactive sources of 137Cs (662 keV), 60Co (1173 keV and 1333 keV), 22Na (511 keV and 1275 keV) and 133Ba (355 keV) was used. The operating voltage of the photomultiplier was 2700 V for the detection of gamma rays and the accumulation time in the counting process was 600 s. The crystals used in gamma spectroscopy were cut with dimensions of 20 mm in diameter and 20 mm in height. The scintillator response to neutron radiation from a radioactive source of Am/Be with energy range of 1 MeV to 12 MeV was available. The activity of the AmBe source was 1Ci Am. The fluency was 2.6 x 106 neutrons / second. The operating voltage of the photomultiplier tube was 1300 V. The accumulation time in the counting process was 600 s. The scintillator crystals were cut with dimensions of 20 mm diameter and 10 mm height. With the results obtained, it may be observed that the crystals are sensitive to these radiations.pt_BR
dc.event.siglaINACpt_BR
dc.identifier.citationPEREIRA, MARIA da C.C.; MADI FILHO, TUFIC; BERRETTA, JOSE R.; TOMAZ, LUCAS F.; PINTO, MARLENE C. Characteristics of Pb2+ doped CsI matriz under gamma and neutron excitations. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. <b>Proceedings...</b> Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017. Disponível em: http://repositorio.ipen.br/handle/123456789/28299.
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28299
dc.localRio de Janeiro, RJpt_BR
dc.local.eventoBelo Horizonte, MGpt_BR
dc.publisherAssociação Brasileira de Energia Nuclearpt_BR
dc.rightsopenAccesspt_BR
dc.subjectannealing
dc.subjectbarium 122
dc.subjectbridgman method
dc.subjectcesium 137
dc.subjectcesium iodides
dc.subjectcobalt 60
dc.subjectcrystals
dc.subjectdoped materials
dc.subjectgamma radiation
dc.subjectgamma spectroscopy
dc.subjectlead
dc.subjectsodium 22
dc.titleCharacteristics of Pb2+ doped CsI matriz under gamma and neutron excitationspt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorLUCAS FAUSTINO TOMAZ
ipen.autorMARLENE CRISTINA PINTO
ipen.autorJOSE ROBERTO BERRETTA
ipen.autorTUFIC MADI FILHO
ipen.autorMARIA DA CONCEICAO COSTA PEREIRA
ipen.codigoautor14233
ipen.codigoautor14547
ipen.codigoautor710
ipen.codigoautor1231
ipen.codigoautor193
ipen.contributor.ipenauthorLUCAS FAUSTINO TOMAZ
ipen.contributor.ipenauthorMARLENE CRISTINA PINTO
ipen.contributor.ipenauthorJOSE ROBERTO BERRETTA
ipen.contributor.ipenauthorTUFIC MADI FILHO
ipen.contributor.ipenauthorMARIA DA CONCEICAO COSTA PEREIRA
ipen.date.recebimento18-01pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc24134pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication9a284afb-a21d-466b-95f5-f54ad91876af
relation.isAuthorOfPublication582c3230-1339-40b9-bccf-0b732c786e86
relation.isAuthorOfPublicatione05a9eb7-8471-4f24-9991-018ed148a2e2
relation.isAuthorOfPublicationc6d485fe-9927-427a-93a0-0104d2bf801e
relation.isAuthorOfPublication9dc6d02e-963a-42fd-96d8-d9d18a3ec6a8
relation.isAuthorOfPublication.latestForDiscovery9dc6d02e-963a-42fd-96d8-d9d18a3ec6a8
sigepi.autor.atividadePEREIRA, MARIA DA C.C.:193:240:Spt_BR
sigepi.autor.atividadeMADI FILHO, TUFIC:1231:420:Npt_BR
sigepi.autor.atividadeBERRETTA, JOSE R.:710:430:Npt_BR
sigepi.autor.atividadeTOMAZ, LUCAS F.:14233:240:Npt_BR
sigepi.autor.atividadePINTO, MARLENE C.:14547:-1:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24134.pdf
Tamanho:
439.86 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções