Characterization of a free air ionization chamber for low energy X-rays
| dc.contributor.author | SILVA, NATALIA F. DA | |
| dc.contributor.author | XAVIER, M. | |
| dc.contributor.author | VIVOLO, V. | |
| dc.contributor.author | CALDAS, L.V.E. | |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2017-09-28T11:02:27Z | |
| dc.date.available | 2017-09-28T11:02:27Z | |
| dc.date.issued | 2016 | pt_BR |
| dc.description.abstract | Free air ionization chambers are used by most primary metrology laboratories as primary standards of the quantities air kerma and exposure in X-ray beams. The free air ionization chamber for low energies of the Calibration Laboratory (LCI) of IPEN showed in a characterization test a problem in the set responsible for the variation of its sensitive volume. After a modification in the support of the micrometers used for the movement of the internal cylinder and the establishment of a new alignment system protocol, the tests were redone. The objective of this work was to present the results obtained in the new condition. | pt_BR |
| dc.format.extent | 1-5 | pt_BR |
| dc.identifier.citation | SILVA, NATALIA F. DA; XAVIER, M.; VIVOLO, V.; CALDAS, L.V.E. Characterization of a free air ionization chamber for low energy X-rays. <b>Journal of Physics: Conference Series</b>, v. 733, p. 1-5, 2016. DOI: <a href="https://dx.doi.org/10.1088/1742-6596/733/1/012090">10.1088/1742-6596/733/1/012090</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/27804. | |
| dc.identifier.doi | 10.1088/1742-6596/733/1/012090 | pt_BR |
| dc.identifier.issn | 1742-6588 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/27804 | |
| dc.identifier.vol | 733 | pt_BR |
| dc.relation.ispartof | Journal of Physics: Conference Series | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | calibration | |
| dc.subject | ionization | |
| dc.subject | standards | |
| dc.subject | ionization chambers | |
| dc.subject | air | |
| dc.subject | alignment | |
| dc.subject | cylinders | |
| dc.subject | kerma | |
| dc.subject | modifications | |
| dc.subject | variations | |
| dc.subject | x radiation | |
| dc.title | Characterization of a free air ionization chamber for low energy X-rays | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.autor | VITOR VIVOLO | |
| ipen.autor | MARCOS XAVIER | |
| ipen.autor | NATALIA FIORINI DA SILVA | |
| ipen.codigoautor | 1495 | |
| ipen.codigoautor | 406 | |
| ipen.codigoautor | 712 | |
| ipen.codigoautor | 12139 | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.contributor.ipenauthor | VITOR VIVOLO | |
| ipen.contributor.ipenauthor | MARCOS XAVIER | |
| ipen.contributor.ipenauthor | NATALIA FIORINI DA SILVA | |
| ipen.date.recebimento | 17-09 | pt_BR |
| ipen.identifier.fi | Sem F.I. | pt_BR |
| ipen.identifier.ipendoc | 23115 | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication | 6875184b-48f2-43e7-b6de-e676ee5db15a | |
| relation.isAuthorOfPublication | d0233a99-c67a-41f8-9d92-cbce7c44a54e | |
| relation.isAuthorOfPublication | c8a4b1ff-5955-47b9-a15a-ecbd12a4baa8 | |
| relation.isAuthorOfPublication.latestForDiscovery | c8a4b1ff-5955-47b9-a15a-ecbd12a4baa8 | |
| sigepi.autor.atividade | SILVA, NATALIA F. DA:12139:-1:S | pt_BR |
| sigepi.autor.atividade | XAVIER, M.:712:330:N | pt_BR |
| sigepi.autor.atividade | VIVOLO, V.:406:330:N | pt_BR |
| sigepi.autor.atividade | CALDAS, L.V.E.:1495:330:N | pt_BR |