Mass attenuation coefficients of X-rays in different barite concrete used in radiation protection as shielding against ionizing radiation

dc.contributor.authorALMEIDA JUNIOR, T.A.
dc.contributor.authorNOGUEIRA, M.S.
dc.contributor.authorVIVOLO, V.
dc.contributor.authorPOTIENS, M.P.A.
dc.contributor.authorCAMPOS, L.L.
dc.coverageInternacionalpt_BR
dc.date.accessioned2017-09-14T12:24:11Z
dc.date.available2017-09-14T12:24:11Z
dc.date.issued2017pt_BR
dc.description.abstractThe probability of a photon interacting in a particular way with a given material, per unit path length, is usually called the linear attenuation coefficient (μ), and it is of great importance in radiation shielding. Plates of barite concrete with different thickness were fabricated in order to determining their mass attenuation coefficients at different energies. The plates were irradiated with ISO X-ray beams (N60, N80, N110 and N150), generated by Pantak HF320 X-ray equipment, at the IPEN laboratory. The mass attenuation coefficients of barite concrete have been measured using X-ray attenuation for different thicknesses of barite concrete qualities of the ISO. The attenuator material issued from different regions of Brazil. The experimental procedure in this research was validated by comparison between the experimental measurements of mass attenuation coefficients and coefficients determined by the same atomic composition, using as a tool to XCOM. The highest value of (μ/ ρ) found experimentally was in the energy of 48 keV, in ISO 60 N quality, being 1.32( ± 0.49) for purple barite; 1.47( ± 0.41) for white barite and 1.75( ± 0.41) for cream barite. The determination of the chemical composition of the barite samples was of fundamental importance for the characterization of these materials. It can be seen that both calculated and measured data for the linear attenuation coefficients increase with the increasing materials density, as it is expected. It can be concluded that the photon attenuation coefficients depends on the photon energy and the materials density is the main contribution to the photon attenuation coefficients, which is important for radiation shielding.pt_BR
dc.format.extent349-354pt_BR
dc.identifier.citationALMEIDA JUNIOR, T.A.; NOGUEIRA, M.S.; VIVOLO, V.; POTIENS, M.P.A.; CAMPOS, L.L. Mass attenuation coefficients of X-rays in different barite concrete used in radiation protection as shielding against ionizing radiation. <b>Radiation Physics and Chemistry</b>, v. 140, p. 349-354, 2017. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2017.02.054">10.1016/j.radphyschem.2017.02.054</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/27727.
dc.identifier.doi10.1016/j.radphyschem.2017.02.054pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.percentilfi43.27en
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/27727
dc.identifier.vol140pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.subjectattenuation
dc.subjectbarite
dc.subjectionizing radiations
dc.subjectradiation protection
dc.subjectshielding
dc.subjectx radiation
dc.subjectchemical composition
dc.subjectconcretes
dc.subjectiso
dc.subjectkev range 10-100
dc.subjectmass
dc.subjectphotons
dc.subjectraw materials
dc.titleMass attenuation coefficients of X-rays in different barite concrete used in radiation protection as shielding against ionizing radiationpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorVITOR VIVOLO
ipen.codigoautor1195
ipen.codigoautor346
ipen.codigoautor406
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorVITOR VIVOLO
ipen.date.recebimento17-09pt_BR
ipen.identifier.fi1.435pt_BR
ipen.identifier.ipendoc23025pt_BR
ipen.identifier.ods7
ipen.identifier.ods9
ipen.identifier.ods12
ipen.range.fi0.001 - 1.499
ipen.range.percentilfi25.00 - 49.99
ipen.type.genreArtigo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication6875184b-48f2-43e7-b6de-e676ee5db15a
relation.isAuthorOfPublication.latestForDiscovery6875184b-48f2-43e7-b6de-e676ee5db15a
sigepi.autor.atividadeVIVOLO, V.:406:330:Npt_BR
sigepi.autor.atividadePOTIENS, M.P.A.:346:330:Npt_BR
sigepi.autor.atividadeCAMPOS, L.L.:1195:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
23025.pdf
Tamanho:
500.54 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções