Utilization of Tandem systems for the detection of impurities in radiopharmaceuticals

dc.contributor.authorCECATTI, S.G.P.pt_BR
dc.contributor.authorCALDAS, L.V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 11thpt_BR
dc.date.accessioned2014-11-17T18:33:35Zpt_BR
dc.date.accessioned2014-11-18T18:45:32Zpt_BR
dc.date.accessioned2015-04-01T23:19:43Z
dc.date.available2014-11-17T18:33:35Zpt_BR
dc.date.available2014-11-18T18:45:32Zpt_BR
dc.date.available2015-04-01T23:19:43Z
dc.date.evento23-28 May, 2004pt_BR
dc.description.abstractIn this work tandem systems were established and characterized using four cylindrical absorbers of materials with different densities for an additional quality control test. The study was performed using two secondary standard systems NPL and a homemade system composed by a well-type ionization chamber made at IPEN and a Keithley electrometer. For the establishment of the tandem systems non sealed sources were utilized. The samples with impurities were measured using combinations with different proportions of radionuclides. The ratio between the measurements with different absorbers presented constant values for each dose calibrator and pure source. The results obtained with the materials with impurities using the absorbers presented constant, but different values, depending on the impurity and its proportion in the mixture. Therefore, the use of tandem systems may be recommended for quality control programs.
dc.event.siglaIRPApt_BR
dc.identifier.citationCECATTI, S.G.P.; CALDAS, L.V.E. Utilization of Tandem systems for the detection of impurities in radiopharmaceuticals. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 11th, 23-28 May, 2004, Madrid, Spain. Disponível em: http://repositorio.ipen.br/handle/123456789/17521.
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/17521pt_BR
dc.local.eventoMadrid, Spainpt_BR
dc.rightsopenAccesspt_BR
dc.subjectradiopharmaceuticalspt_BR
dc.subjectimpuritiespt_BR
dc.subjectionization chamberspt_BR
dc.subjectquality controlpt_BR
dc.titleUtilization of Tandem systems for the detection of impurities in radiopharmaceuticalspt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorSONIA GARCIA PEREIRA CECATTI
ipen.codigoautor1495
ipen.codigoautor2793
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorSONIA GARCIA PEREIRA CECATTI
ipen.date.recebimento05-10pt_BR
ipen.event.datapadronizada2004pt_BR
ipen.identifier.ipendoc10801pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication6187a764-7aa8-4a06-85f3-6c8cedef1709
relation.isAuthorOfPublication.latestForDiscovery6187a764-7aa8-4a06-85f3-6c8cedef1709
sigepi.autor.atividadeCECATTI, S.G.P.:2793:28:Spt_BR
sigepi.autor.atividadeCALDAS, L.V.E.:1495:28:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
10801.pdf
Tamanho:
84.76 KB
Formato:
Adobe Portable Document Format

Coleções