Application of multivariate calibration for simultaneous determination of major and minor constituents in Usub(3)SiSub(2) by WDXRF technique
| dc.contributor.author | SCAPIN, MARCOS A. | |
| dc.contributor.author | SILVA, CLAYTON P. | |
| dc.contributor.author | COTRIM, MARYCEL E.B. | |
| dc.contributor.author | PIRES, MARIA A.F. | |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2014-09-09T14:27:20Z | |
| dc.date.available | 2014-09-09T14:27:20Z | |
| dc.date.issued | 2014 | pt_BR |
| dc.description.abstract | The aim of this work was to implement and to validate the multivariate calibration for simultaneous determination of major and minor constituents in uranium nuclear fuel by WDXRF technique. The method is nondestructive and involves no chemical treatments thus is possible to perform fast chemical analysis and produces no hazardous waste. The precision and accuracy achieved are statistically comparable to others sensitive techniques like ICP-OES for impurities determination. | |
| dc.format.extent | 1-9 | pt_BR |
| dc.identifier.citation | SCAPIN, MARCOS A.; SILVA, CLAYTON P.; COTRIM, MARYCEL E.B.; PIRES, MARIA A.F. Application of multivariate calibration for simultaneous determination of major and minor constituents in Usub(3)SiSub(2) by WDXRF technique. <b>Journal of Radioanalytical and Nuclear Chemistry</b>, p. 1-9, 2014. DOI: <a href="https://dx.doi.org/10.1007/s10967-014-3332-6">10.1007/s10967-014-3332-6</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/9035. | |
| dc.identifier.doi | 10.1007/s10967-014-3332-6 | |
| dc.identifier.issn | 0236-5731 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-6462-4758 | |
| dc.identifier.orcid | https://orcid.org/0000-0002-0606-4369 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/9035 | |
| dc.relation.ispartof | Journal of Radioanalytical and Nuclear Chemistry | pt_BR |
| dc.rights | openAccess | |
| dc.subject | uranium silicates | |
| dc.subject | nuclear fuels | |
| dc.subject | calibration | |
| dc.subject | multivariate analysis | |
| dc.subject | x-ray fluorescence analysis | |
| dc.title | Application of multivariate calibration for simultaneous determination of major and minor constituents in Usub(3)SiSub(2) by WDXRF technique | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | MARIA APARECIDA FAUSTINO PIRES | |
| ipen.autor | MARYCEL ELENA BARBOZA COTRIM | |
| ipen.autor | CLAYTON PEREIRA DA SILVA | |
| ipen.autor | MARCOS ANTONIO SCAPIN | |
| ipen.codigoautor | 1327 | |
| ipen.codigoautor | 515 | |
| ipen.codigoautor | 6418 | |
| ipen.codigoautor | 836 | |
| ipen.contributor.ipenauthor | MARIA APARECIDA FAUSTINO PIRES | |
| ipen.contributor.ipenauthor | MARYCEL ELENA BARBOZA COTRIM | |
| ipen.contributor.ipenauthor | CLAYTON PEREIRA DA SILVA | |
| ipen.contributor.ipenauthor | MARCOS ANTONIO SCAPIN | |
| ipen.date.recebimento | 14-09 | pt_BR |
| ipen.identifier.fi | 1.034 | pt_BR |
| ipen.identifier.ipendoc | 20122 | pt_BR |
| ipen.identifier.ods | 12 | |
| ipen.range.fi | 0.001 - 1.499 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 2254b498-a2dd-4f3f-a64d-d0d6e8a3acdf | |
| relation.isAuthorOfPublication | cc013e19-0c8e-4f8c-845f-f2ff7471b78a | |
| relation.isAuthorOfPublication | a63ae72a-758c-441c-a4e3-74e25c58ba9e | |
| relation.isAuthorOfPublication | a95b0a15-62ca-4080-a98a-c8a63c940bc1 | |
| relation.isAuthorOfPublication.latestForDiscovery | a95b0a15-62ca-4080-a98a-c8a63c940bc1 | |
| sigepi.autor.atividade | SCAPIN, MARCOS A.:836:510:S | |
| sigepi.autor.atividade | SILVA, CLAYTON P.:6418:-1:N | |
| sigepi.autor.atividade | COTRIM, MARYCEL E.B.:515:510:N | |
| sigepi.autor.atividade | PIRES, MARIA A.F.:1327:510:N |