Evaluation of the biotribological behavior and cytotoxicity of laser-textured ISO 5832-1 stainless steel for use in orthopedic implants

dc.contributor.authorPIERETTI, EURICO F.
dc.contributor.authorRODAS, ANDREA C.D.
dc.contributor.authorANTUNES, RENATO A.
dc.contributor.authorNEVES, MAURICIO D.M.
dc.contributor.editorJOHNSON, DAVID
dc.coverageInternacionalpt_BR
dc.date.accessioned2019-02-01T12:17:57Z
dc.date.available2019-02-01T12:17:57Z
dc.date.issued2018pt_BR
dc.description.abstractThis chapter evaluated the influence of laser texturing process on the tribological behavior of the ISO 5832-1 austenitic stainless steel (SS). The friction coefficient and wear were determined using ball-cratering wear tests. The laser texturing process was carried out with a nanosecond optical fiber ytterbium laser at four different pulse frequencies. Cytotoxicity tests were carried out to determine if laser texturing affects the biomaterial biocompatibility. For comparison reasons, pristine surfaces were also evaluated. The results indicated that the wear volume and friction coefficient were reduced after laser texturing. The samples were considered noncytotoxic according to the biocompatibility tests as the laser texturing process did not decrease cell’s viability.pt_BR
dc.format.extent65-76pt_BR
dc.identifier.capitulo4pt_BR
dc.identifier.citationPIERETTI, EURICO F.; RODAS, ANDREA C.D.; ANTUNES, RENATO A.; NEVES, MAURICIO D.M. Evaluation of the biotribological behavior and cytotoxicity of laser-textured ISO 5832-1 stainless steel for use in orthopedic implants. In: JOHNSON, DAVID (ed.). <b>Tribology, Lubricants and Additives</b>. London: IntechOpen, 2018. , cap. 4. p. 65-76. DOI: <a href="https://dx.doi.org/10.5772/intechopen.73140">10.5772/intechopen.73140</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/29455.
dc.identifier.doi10.5772/intechopen.73140pt_BR
dc.identifier.orcidaguardandopt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-1304-2117
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/29455
dc.localLondonpt_BR
dc.publisherIntechOpenpt_BR
dc.rightsopenAccesspt_BR
dc.subjectantimitotic drugs
dc.subjecttoxicity
dc.subjectstainless steels
dc.subjecttribology
dc.subjectlasers
dc.subjecttexture
dc.subjectimplants
dc.titleEvaluation of the biotribological behavior and cytotoxicity of laser-textured ISO 5832-1 stainless steel for use in orthopedic implantspt_BR
dc.title.livroTribology, Lubricants and Additivespt_BR
dc.typeCapítulo de livropt_BR
dspace.entity.typePublication
ipen.autorEURICO FELIX PIERETTI
ipen.autorMAURICIO DAVID MARTINS DAS NEVES
ipen.codigoautor9762
ipen.codigoautor19
ipen.contributor.ipenauthorEURICO FELIX PIERETTI
ipen.contributor.ipenauthorMAURICIO DAVID MARTINS DAS NEVES
ipen.date.recebimento19-02pt_BR
ipen.identifier.ipendoc25248pt_BR
ipen.type.genreCapítulo
relation.isAuthorOfPublication81bdc39e-9843-47fe-bbed-2ab1670d694a
relation.isAuthorOfPublication99e4f42a-cdfa-4da0-a1fc-4788ca55471c
relation.isAuthorOfPublication.latestForDiscovery81bdc39e-9843-47fe-bbed-2ab1670d694a
sigepi.autor.atividadePIERETTI, EURICO F.:9762:-1:Spt_BR
sigepi.autor.atividadeNEVES, MAURICIO D.M.:19:730:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25248.pdf
Tamanho:
1.6 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções