Computational modeling of CyberKnife® system using the Monte Carlo method

dc.contributor.authorGRANJA, ALINE A. C.
dc.contributor.authorANTUNES, PAULA C. G.
dc.contributor.authorJESUS, GABRIELA R. S.
dc.contributor.authorCARDOSO, PEDRO H. B.
dc.contributor.authorSHORTO, JULIAN M. B.
dc.coverageNacional
dc.date.accessioned2026-10-06T13:37:39Z
dc.date.available2026-10-06T13:37:39Z
dc.date.issued2026
dc.description.abstractThe accuracy required in small-field dosimetry for stereotactic radiosurgery imposes limitations on the conventional dosimetric calibration protocols used in radiotherapy. This study presents the development and validation of a computational model of the CyberKnife® system using the Monte Carlo method with the MCNP6 code. The main objective is to establish a validated computational model that enables future research and clinical applications in stereotactic radiosurgery. The model was developed to validate the 60 mm conical collimator, and the results were compared with experimental data from percentage depth dose (PDD) and lateral dose profile (LDP) curves at depths of 10 cm and 20 cm. The analyses revealed the influence of field size and photon-source characteristics on the dose distribution, with good agreement between simulated and measured data within the established tolerance limits. These findings demonstrate that the proposed model accurately reproduces the CyberKnife® beam behavior and serves as a robust and promising tool for investigating treatment variables, supporting therapeutic planning, and optimizing stereotactic radiosurgery protocols.
dc.format.extent1-6
dc.identifier.citationGRANJA, ALINE A. C.; ANTUNES, PAULA C. G.; JESUS, GABRIELA R. S.; CARDOSO, PEDRO H. B.; SHORTO, JULIAN M. B. Computational modeling of CyberKnife® system using the Monte Carlo method. <b>Revista Brasileira de Física Médica</b>, v. 20, p. 1-6, 2026. DOI: <a href="https://dx.doi.org/10.29384/rbfm.2026.v20.19849001874">10.29384/rbfm.2026.v20.19849001874</a>. Disponível em: https://repositorio.ipen.br/handle/123456789/50209.
dc.identifier.doi10.29384/rbfm.2026.v20.19849001874
dc.identifier.issn2176-8978
dc.identifier.orcidhttps://orcid.org/0000-0003-4817-5275
dc.identifier.percentilfiSem Percentil F.I.
dc.identifier.percentilfiCiteScoreSem Percentil CiteScore
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/50209
dc.identifier.vol20
dc.language.isoeng
dc.relation.ispartofRevista Brasileira de Física Médica
dc.rightsopenAccess
dc.titleComputational modeling of CyberKnife® system using the Monte Carlo method
dc.title.alternativeModelagem computacional do sistema CyberKnife® utilizando o método de Monte Carlo
dc.typeArtigo de periódico
dspace.entity.typePublication
ipen.autorALINE APARECIDA DA COSTA GRANJA
ipen.autorJULIAN MARCO BARBOSA SHORTO
ipen.codigoautor15587
ipen.codigoautor9690
ipen.contributor.ipenauthorALINE APARECIDA DA COSTA GRANJA
ipen.contributor.ipenauthorJULIAN MARCO BARBOSA SHORTO
ipen.identifier.fiSem F.I.
ipen.identifier.fiCiteScoreSem CiteseScore
ipen.identifier.ipendoc32294
ipen.type.genreArtigo
relation.isAuthorOfPublicationc836d790-f0a3-43a1-b486-d22c7a608ce7
relation.isAuthorOfPublication91a9cbb6-cd24-480c-a65d-dd1c309a1622
relation.isAuthorOfPublication.latestForDiscoveryc836d790-f0a3-43a1-b486-d22c7a608ce7
sigepi.autor.atividadeALINE APARECIDA DA COSTA GRANJA:15587:420:N
sigepi.autor.atividadeJULIAN MARCO BARBOSA SHORTO:9690:420:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
32294.pdf
Tamanho:
1015.88 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções