Evaluation in vitro and in vivo of biomimetic hydroxyapatite coated on titanium dental implants
| dc.contributor.author | RIGO, E.C.S. | |
| dc.contributor.author | BOSCHI, A.O. | |
| dc.contributor.author | YOSHIMOTO, M. | |
| dc.contributor.author | ALLEGRINI JUNIOR, S. | |
| dc.contributor.author | KONIG JUNIOR, B. | |
| dc.contributor.author | CARBONARI, M.J. | |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2016-09-22T18:37:49Z | |
| dc.date.available | 2016-09-22T18:37:49Z | |
| dc.date.issued | 2004 | pt_BR |
| dc.format.extent | 647-651 | pt_BR |
| dc.identifier.citation | RIGO, E.C.S.; BOSCHI, A.O.; YOSHIMOTO, M.; ALLEGRINI JUNIOR, S.; KONIG JUNIOR, B.; CARBONARI, M.J. Evaluation in vitro and in vivo of biomimetic hydroxyapatite coated on titanium dental implants. <b>Materials Science and Engineering C</b>, v. 24, n. 5, p. 647-651, 2004. Disponível em: http://repositorio.ipen.br/handle/123456789/26710. | |
| dc.identifier.fasciculo | 5 | pt_BR |
| dc.identifier.issn | 0928-4931 | pt_BR |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/26710 | |
| dc.identifier.vol | 24 | pt_BR |
| dc.relation.ispartof | Materials Science and Engineering C | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | coatings | |
| dc.subject | biomimetic processes | |
| dc.subject | titanium | |
| dc.subject | implants | |
| dc.subject | apatites | |
| dc.subject | evaluation | |
| dc.subject | in vitro | |
| dc.subject | in vivo | |
| dc.subject | coatings | |
| dc.subject | bone tissues | |
| dc.subject | ceramics | |
| dc.subject | electrodeposition | |
| dc.subject | glass | |
| dc.subject | infrared spectra | |
| dc.subject | scanning electron microscopy | |
| dc.subject | sodium silicates | |
| dc.subject | spectroscopy | |
| dc.subject | temperature range 0273-0400 k | |
| dc.subject | temperature range 0065-0273 k | |
| dc.subject | fourier transformation | |
| dc.subject | dentistry | |
| dc.title | Evaluation in vitro and in vivo of biomimetic hydroxyapatite coated on titanium dental implants | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | MARCELO JOSE CARBONARI | |
| ipen.codigoautor | 2759 | |
| ipen.contributor.ipenauthor | MARCELO JOSE CARBONARI | |
| ipen.date.recebimento | 16-09 | pt_BR |
| ipen.identifier.fi | 1.383 | pt_BR |
| ipen.identifier.ipendoc | 22596 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.range.fi | 0.001 - 1.499 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 9bf08f8f-ff4b-4da8-add4-76efda7c4890 | |
| relation.isAuthorOfPublication.latestForDiscovery | 9bf08f8f-ff4b-4da8-add4-76efda7c4890 | |
| sigepi.autor.atividade | CARBONARI, M.J.:2759:-1:N | pt_BR |