Application of the Reduced-Fitting Method to determine neutron scattering

dc.contributor.authorALVARENGA, TALLYSON S.pt_BR
dc.contributor.authorPOLO, IVON O.pt_BR
dc.contributor.authorPEREIRA, WALSAN W.pt_BR
dc.contributor.authorMAYHUGH, MICHAEL R.pt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2020-12-03T18:58:25Z
dc.date.available2020-12-03T18:58:25Z
dc.date.issued2021pt_BR
dc.description.abstractAs the number of techniques using neutron radiation has grown, the number of neutrons detectors has increased along with need for their calibration. In Brazil this substantial demand for neutron detector calibration falls on a single laboratory located in Rio de Janeiro. One of the major problems in the calibration of neutron detectors is neutron scattering, which varies depending on the size and configuration of the laboratory. This is due to the neutrons that interact with the experimental setup and the surrounding, walls, floor and ceiling. This scatter influences the reading of the instrument to be calibrated and causes systematic errors in the calibration of neutron detectors. ISO 8529-2 recommends the following methods to correct these effects: The Semi-Empirical Method (SEM), the Reduced-Fitting Method (RFM), the Shadow-Cone Method (SCM) and the Generalized Fit Method (GFM). In this study, the neutron scattering characterization was performed in the Neutron Calibration Laboratory (LCN) of IPEN/CNEN, using the RFM method. The neutron source used was 241AmBe, which was positioned in the center of the calibration room. Neutron spectra were obtained using a scintillation detector based on 6Lil(Eu) in combination with a Bonner sphere spectrometer (BSS) at source-detector distances from 30 cm to 258 cm.pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipComissão Nacional de Energia Nuclear (CNEN)pt_BR
dc.description.sponsorshipIDCNPq: 301335/2016-8pt_BR
dc.description.sponsorshipIDCNEN: 01342.002316/2019-46pt_BR
dc.format.extent1-8pt_BR
dc.identifier.citationALVARENGA, TALLYSON S.; POLO, IVON O.; PEREIRA, WALSAN W.; MAYHUGH, MICHAEL R.; CALDAS, LINDA V.E. Application of the Reduced-Fitting Method to determine neutron scattering. <b>Radiation Physics and Chemistry</b>, v. 179, p. 1-8, 2021. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2020.109207">10.1016/j.radphyschem.2020.109207</a>. Disponível em: http://200.136.52.105/handle/123456789/31588.
dc.identifier.doi10.1016/j.radphyschem.2020.109207pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.percentilfi57.09pt_BR
dc.identifier.percentilfiCiteScore70.00
dc.identifier.urihttp://200.136.52.105/handle/123456789/31588
dc.identifier.vol179pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.subjectscattering
dc.subjectneutrons
dc.subjectradiations
dc.subjectneutron detectors
dc.subjectcalibration
dc.subjectcalculation methods
dc.subjectbonner sphere spectrometers
dc.subjectneutron spectra
dc.titleApplication of the Reduced-Fitting Method to determine neutron scatteringpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorIVON ORAMAS POLO
ipen.autorTALLYSON SARMENTO ALVARENGA
ipen.codigoautor1495
ipen.codigoautor14120
ipen.codigoautor10924
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorIVON ORAMAS POLO
ipen.contributor.ipenauthorTALLYSON SARMENTO ALVARENGA
ipen.date.recebimento20-12
ipen.identifier.fi2.776pt_BR
ipen.identifier.fiCiteScore4.5
ipen.identifier.ipendoc27360pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.identifier.ods7
ipen.identifier.ods9
ipen.identifier.ods12
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication685f842c-100e-4c4e-ad40-d73c77cc2a75
relation.isAuthorOfPublicationd7d9e0d3-bfb9-4a3c-b5c7-e84d2d1e18b9
relation.isAuthorOfPublication.latestForDiscoveryd7d9e0d3-bfb9-4a3c-b5c7-e84d2d1e18b9
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR
sigepi.autor.atividadePOLO, IVON O.:14120:330:Npt_BR
sigepi.autor.atividadeALVARENGA, TALLYSON S.:10924:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27360.pdf
Tamanho:
4.43 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções