Dose calibrator and gamma counter

dc.contributor.authorSILVA, VITOR M.A. dapt_BR
dc.contributor.authorSOUSA, JURANDIR A. dept_BR
dc.contributor.authorMARTINS, PATRICIA de A.pt_BR
dc.contributor.authorFUKUMORI, NEUZA T.O.pt_BR
dc.contributor.authorSILVA, NATANAEL G. dapt_BR
dc.contributor.authorMATSUDA, MARGARETH M.N.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2020-01-07T13:57:06Z
dc.date.available2020-01-07T13:57:06Z
dc.date.eventoOctober 21-25, 2019pt_BR
dc.description.abstractTo ensure that pharmaceutical products have and maintain the structure, identity, purity, concentration, potency and safety characteristics required for their use, there is a set of standard procedures called Good Manufacturing Practices (GMP). In Brazil, the National Sanitary Surveillance Agency (ANVISA) regulates the GMP production of medicines through RDC17/2010 and for radiopharmaceuticals through RDC 63/2009 and 38/2008, to ensure their safe and correct use in commercial production and nuclear medicine services, respectively. Most 99mTc radiopharmaceutical monographs have biological distribution specifications. Using invasive method, 99mTcradiopharmaceuticalsare assessed by the injection into animals of defined strains and the radioactivity (as percentage of retainedor injected dose -%RDor%ID)ismeasured in specified organs. Technetium-99m Sestamibi radiopharmaceutical (99mTc-2-methoxy-isobutyl-isonitrile; 99mTc-sestamibi; MIBI-TEC®) monograph is related in USP 41, but the biological distribution assay is not included. At IPEN, the biodistribution test is performed as established in the Radiopharmaceutical Quality Control Manual of ARCAL XV (1999) - International Atomic Energy Agency (IAEA), for each batch. The objective of this work is to compare MIBI-TEC®biodistribution results using dose calibrator and gamma counter with sodium iodide detector by measuring the radioactivity in the organs. Three batches of MIBI-TEC®were used and 1 vial of lyophilized reagent (LR) was labeled with 5-10 mCiin 1-3 mL of 99mTc eluate. 200-300 μCi in 0.2 mLwereinjected in 3 Balb-Cmice. After 30 minutes of biodistribution, heart, lung, muscle, liver, paw, column and tail were withdrawn, weighed and radioactivity was measured in dose calibrator and gamma counter (μCi andcpm, respectively). %ID/g ratio in the organs of interest was calculated using the data obtained by both equipment and the results were compared. No significant differences were observed and it was possible to conclude that either a dose calibrator or a gamma counter can be used in the routine of quality control.pt_BR
dc.event.siglaINACpt_BR
dc.format.extent1860-1864pt_BR
dc.identifier.citationSILVA, VITOR M.A. da; SOUSA, JURANDIR A. de; MARTINS, PATRICIA de A.; FUKUMORI, NEUZA T.O.; SILVA, NATANAEL G. da; MATSUDA, MARGARETH M.N. Dose calibrator and gamma counter: comparison of results in MIBI-TEC® biological distribution. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. <b>Proceedings...</b> Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1860-1864. Disponível em: http://repositorio.ipen.br/handle/123456789/30589.
dc.identifier.orcid0000-0003-4455-3486pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-4455-3486
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30589
dc.localRio de Janeiropt_BR
dc.local.eventoSantos, SPpt_BR
dc.publisherAssociação Brasileira de Energia Nuclear
dc.rightsopenAccesspt_BR
dc.subjectcalibration
dc.subjectcomparative evaluations
dc.subjectquality control
dc.subjectradiation detectors
dc.subjectradiation dose distributions
dc.subjectradiation doses
dc.subjectradioactivity
dc.subjectradiopharmaceuticals
dc.subjectsodium iodides
dc.subjecttechnetium 99
dc.titleDose calibrator and gamma counterpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorMARGARETH MIE NAKAMURA MATSUDA
ipen.autorNATANAEL GOMES DA SILVA
ipen.autorNEUZA TAEKO OKASAKI FUKUMORI
ipen.autorPATRICIA DE ANDRADE MARTINS
ipen.autorJURANDIR ALVES DE SOUSA
ipen.autorVITOR MIZAEL ANGELI DA SILVA
ipen.codigoautor841
ipen.codigoautor750
ipen.codigoautor1514
ipen.codigoautor965
ipen.codigoautor1067
ipen.codigoautor15132
ipen.contributor.ipenauthorMARGARETH MIE NAKAMURA MATSUDA
ipen.contributor.ipenauthorNATANAEL GOMES DA SILVA
ipen.contributor.ipenauthorNEUZA TAEKO OKASAKI FUKUMORI
ipen.contributor.ipenauthorPATRICIA DE ANDRADE MARTINS
ipen.contributor.ipenauthorJURANDIR ALVES DE SOUSA
ipen.contributor.ipenauthorVITOR MIZAEL ANGELI DA SILVA
ipen.date.recebimento20-01
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26239pt_BR
ipen.notas.internasProceedingspt_BR
ipen.subtitulocomparison of results in MIBI-TEC® biological distribution
ipen.type.genreArtigo
relation.isAuthorOfPublicationfa01cabc-d76d-45ee-bb21-4994c14ba167
relation.isAuthorOfPublication7374d7a3-3ba1-4852-b93d-e578e851abd1
relation.isAuthorOfPublicationab0b8070-073b-490b-bc03-17888a1c4f1d
relation.isAuthorOfPublication0fd86237-824c-4605-9f62-9ede89aef62d
relation.isAuthorOfPublication3e62d9f8-fe4c-4a5a-bde4-8dd6c2f7eb7d
relation.isAuthorOfPublication85e48c5b-e8eb-420d-a006-152924d29f48
relation.isAuthorOfPublication.latestForDiscovery85e48c5b-e8eb-420d-a006-152924d29f48
sigepi.autor.atividadeMATSUDA, MARGARETH M.N.:841:110:Npt_BR
sigepi.autor.atividadeSILVA, NATANAEL G. da:750:110:Npt_BR
sigepi.autor.atividadeFUKUMORI, NEUZA T.O.:1514:120:Npt_BR
sigepi.autor.atividadeMARTINS, PATRICIA de A.:965:120:Npt_BR
sigepi.autor.atividadeSOUSA, JURANDIR A. de:1067:-1:Npt_BR
sigepi.autor.atividadeSILVA, VITOR M.A. da:15132:110:S

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26239.pdf
Tamanho:
220.2 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções