Performance of a thin epitaxial diode as a relative dosimeter in radiation protection

dc.contributor.authorGONCALVES, JOSEMARY A.C.
dc.contributor.authorANTONIO, PATRICIA de L.
dc.contributor.authorSANTOS, LEONARDO C. dos
dc.contributor.authorPOTIENS, MARIA da P.A.
dc.contributor.authorCALDAS, LINDA V.E.
dc.contributor.authorBUENO, CARMEN C.
dc.coverageInternacional
dc.creator.eventoSIMPOSIO REPROLAM, 1st
dc.date.accessioned2025-01-21T18:15:45Z
dc.date.available2025-01-21T18:15:45Z
dc.date.eventoNovember 5-8, 2024
dc.description.abstractSilicon diodes have been used as relative dosimeters in radiation protection, medical imaging, and radiation therapy. Usually, the diode operates in the short-circuit current mode and remains unbiased to minimize the dark current contribution to the radiation-induced current signal. The dosimetric parameter is the net output current linearly dependent on the dose rate within certain limits. The corresponding collected charge (obtained as the integral of the current signal) is proportional to the dose. Many articles in the literature report several advantages of diode-based dosimeters despite a key drawback regarding their sensitivity decay with increasing accumulated doses. This issue has been tackled by developing devices with different geometries or tailoring the impurity density in the silicon bulk grown through distinct techniques. A combined approach of these strategies outcomes the epitaxial diode under investigation in this work. It has a thin n-type epitaxial layer (50 μm, 25 mm2) grown on a 300 μm Cz Si substrate. The p+-n junction is provided by a highly doped p-type silicon layer (@ 1 μm) on the front side of the diode. This structure, which keeps the active volume constant with a tiny entrance window and negligible dark current, opens up potential applications for radiation protection dosimetry. The diode is housed in a light-tight polymethylmethacrylate probe with an entrance window covered by a thin (8.3 mg/cm2) black paperboard. The planar pad (p+) signal electrode is directly connected to the input of a Keithley® 6517B electrometer with the backplane n+ grounded and the guard ring structure floating. The current measurements are performed in the shortcircuit mode without externally applied voltage to the diode. The sensitivity, repeatability, reproducibility, dose-response linearity, and directional response are evaluated for N60, N80, N100, and N150 beam qualities [1]. Irradiations are performed with a Pantak-Seifert 160HS Isovolt X-ray generator previously standardized by a Radcal 10X5-180 ionization chamber calibrated at the PTB. The probe is positioned at the center of a circular irradiation field of 42 cm diameter, with 99% homogeneity, at 250 cm from the X-ray tube (focal spot). The current signals produced by photon beams of different qualities (60 -150 kV) are stable and characterized by repeatabilities better than 5%. The dose-responses curves are also linear but slightly dependent on the photon energy. The angular dependence and long-term stability parameters remain to be investigated. To give theoretical support to the data sensitivity calculations, assuming the diode is a thin abrupt junction, are underway.
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIDCNPq: 406303/2022-3; 305142/2021-6
dc.description.sponsorshipIDFAPESP: 18/05982-0; 22/13430-2
dc.identifier.citationGONCALVES, JOSEMARY A.C.; ANTONIO, PATRICIA de L.; SANTOS, LEONARDO C. dos; POTIENS, MARIA da P.A.; CALDAS, LINDA V.E.; BUENO, CARMEN C. Performance of a thin epitaxial diode as a relative dosimeter in radiation protection. In: SIMPOSIO REPROLAM, 1st, November 5-8, 2024, Recife, PE. <b>Abstract...</b> Disponível em: https://repositorio.ipen.br/handle/123456789/48884.
dc.identifier.orcidhttps://orcid.org/0000-0002-8940-9544
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.orcidhttps://orcid.org/0000-0001-7881-7254
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/48884
dc.local.eventoRecife, PE
dc.publisherRed de Optimización de la Protección Radiológica en LatinoAmerica y Caribe
dc.rightsopenAccess
dc.titlePerformance of a thin epitaxial diode as a relative dosimeter in radiation protection
dc.typeResumo de eventos científicos
dspace.entity.typePublication
ipen.autorJOSEMARY ANGELICA CORREA GONCALVES
ipen.autorPATRICIA DE LARA ANTONIO
ipen.autorLEONARDO CAMARGO DOS SANTOS
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorLINDA V. E. CALDAS
ipen.autorCARMEN CECILIA BUENO TOBIAS
ipen.codigoautor924
ipen.codigoautor6585
ipen.codigoautor14459
ipen.codigoautor346
ipen.codigoautor1495
ipen.codigoautor1592
ipen.contributor.ipenauthorJOSEMARY ANGELICA CORREA GONCALVES
ipen.contributor.ipenauthorPATRICIA DE LARA ANTONIO
ipen.contributor.ipenauthorLEONARDO CAMARGO DOS SANTOS
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorCARMEN CECILIA BUENO TOBIAS
ipen.event.datapadronizada2024
ipen.identifier.ipendoc30941
ipen.notas.internasAbstract
ipen.type.genreResumo
relation.isAuthorOfPublication76fdc4d1-7624-4332-a9d0-f06826000679
relation.isAuthorOfPublication5ea4ca8b-8415-4439-81d2-6fe0d6debd42
relation.isAuthorOfPublication07cc589e-6202-469c-a7c3-447c7b828628
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublicationfa74399b-83a0-4f46-91e0-da469104d3f6
relation.isAuthorOfPublication.latestForDiscovery76fdc4d1-7624-4332-a9d0-f06826000679
sigepi.autor.atividadeJOSEMARY ANGELICA CORREA GONCALVES:924:240:N
sigepi.autor.atividadePATRICIA DE LARA ANTONIO:6585:330:N
sigepi.autor.atividadeLEONARDO CAMARGO DOS SANTOS:14459:330:N
sigepi.autor.atividadeMARIA DA PENHA ALBUQUERQUE POTIENS:346:330:N
sigepi.autor.atividadeLINDA V. E. CALDAS:1495:330:N
sigepi.autor.atividadeCARMEN CECILIA BUENO TOBIAS:1592:240:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
30941.pdf
Tamanho:
510.7 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: