Evaluation of the operational characteristics of a CT ionization chamber

dc.contributor.authorMAIA, A.F.pt_BR
dc.contributor.authorCALDAS, L.V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:48:14Zpt_BR
dc.date.accessioned2014-07-30T11:51:09Z
dc.date.available2014-07-15T13:48:14Zpt_BR
dc.date.available2014-07-30T11:51:09Z
dc.date.issued2006pt_BR
dc.description.abstractThe most common ionization chamber used in computed tomography dosimetry is the “pencil ionization chamber”. It is a special cylindrical dosimeter developed for attending computed tomography beams particularities. In this study, a Victoreen pencil ionization chamber was submitted to a set of tests for a detailed evaluation of its operational characteristics. Such as many kinds of detectors, especially field instruments, this ionization chamber had originally a preamplifier to keep it electrically more stable. In this study, the performance of the chamber was analyzed with the original preamplifier and after its removal, and the results were compared. The objective of the preamplifier removal was to enable connecting the chamber to other kinds of electrometers available in laboratories. The behavior of the pencil ionization chamber before and after the removal of the preamplifier was very similar, and the results obtained were always within the limits of international recommendations. The results obtained in both situations allow, if necessary, the preamplifier removal of the system without lack of precision in the measurements.
dc.format.extent65-71pt_BR
dc.identifier.citationMAIA, A.F.; CALDAS, L.V.E. Evaluation of the operational characteristics of a CT ionization chamber. <b>Radiation Measurements</b>, v. 41, n. 1, p. 65-71, 2006. DOI: <a href="https://dx.doi.org/10.1016/j.radmeas.2005.01.005">10.1016/j.radmeas.2005.01.005</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5448.
dc.identifier.doi10.1016/j.radmeas.2005.01.005
dc.identifier.fasciculo1pt_BR
dc.identifier.issn1350-4487pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5448pt_BR
dc.identifier.vol41pt_BR
dc.relation.ispartofRadiation Measurementspt_BR
dc.rightsopenAccessen
dc.subjectionization chamberspt_BR
dc.subjectcomputerized tomographypt_BR
dc.subjectdosimetrypt_BR
dc.subjectpreamplifierspt_BR
dc.subjectelectrometerspt_BR
dc.subjectx radiationpt_BR
dc.subjectradiation qualitypt_BR
dc.subjectenergy dependencept_BR
dc.titleEvaluation of the operational characteristics of a CT ionization chamberpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorANA FIGUEIREDO MAIA
ipen.codigoautor1495
ipen.codigoautor2991
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorANA FIGUEIREDO MAIA
ipen.date.recebimento06-02pt_BR
ipen.identifier.fi0.915pt_BR
ipen.identifier.ipendoc11202pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublicationde6ea8e6-1554-4d6d-b73a-40e3df506cd9
relation.isAuthorOfPublication.latestForDiscoveryde6ea8e6-1554-4d6d-b73a-40e3df506cd9
sigepi.autor.atividadeMAIA, A.F.:2991:28:Spt_BR
sigepi.autor.atividadeCALDAS, L.V.E.:1495:28:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
11202.pdf
Tamanho:
198.51 KB
Formato:
Adobe Portable Document Format

Coleções