Evaluation of medical exposure and exposure by the public in a typical scenario of examinations using mobile X-ray equipment through the Monte Carlo simulation

dc.contributor.authorSANTOS, FELIPE A.
dc.contributor.authorGALEANO, DIEGO C.
dc.contributor.authorSANTOS, WILLIAM S.
dc.contributor.authorCARVALHO JUNIOR, ALBERICO B.
dc.coverageInternacionalpt_BR
dc.date.accessioned2016-09-12T12:41:02Z
dc.date.available2016-09-12T12:41:02Z
dc.date.issued2016pt_BR
dc.description.abstractIn this work irradiation scenarios that simulated chest and abdomen examinations involving mobile X-ray equipment in hospitals were modeled with the purpose of calculating conversion coefficient for effective dose (CCE), normalized to entrance surface dose (ESD), applied to patients and public individuals. These coefficients can easily be used in this practice. Patients and public individuals were represented by a pair of anthropomorphic phantoms inserted in the MCNPX 2.7.0 radiation transport code. One of the phantoms (patient) was irradiated with the direct beam simulating examinations of the chest and abdomen, each with two fields of irradiation, ideal (IF) and extrapolated (EF). Using the software SPECGEN X-ray spectra from 60 to 100 kVp at 10 kVp intervals were generated and used in this work. The other phantom (public individual) was positioned 50–200 cm from the patient. In relation to the CCE calculated in the patient, the average increase obtained between the irradiation fields was 62.4% for the chest examinations, and for the same conditions the CCE was calculated for abdomen examinations and found to be 8.0%. Increasing the distance between public individual and patient, reductions of up to 81.7% in the CCE in abdomen examinations and 83.4% in chest examinations were observed. Through the assessment of CCE of these scenarios, it is possible to measure the damages relating to this practice for both patients and public individuals.
dc.format.extent68-73pt_BR
dc.identifier.citationSANTOS, FELIPE A.; GALEANO, DIEGO C.; SANTOS, WILLIAM S.; CARVALHO JUNIOR, ALBERICO B. Evaluation of medical exposure and exposure by the public in a typical scenario of examinations using mobile X-ray equipment through the Monte Carlo simulation. <b>Radiation Measurements</b>, v. 89, p. 68-73, 2016. Disponível em: http://repositorio.ipen.br/handle/123456789/26622.
dc.identifier.issn1350-4487pt_BR
dc.identifier.percentilfi86.36
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/26622
dc.identifier.vol89pt_BR
dc.relation.ispartofRadiation Measurementspt_BR
dc.rightsopenAccesspt_BR
dc.subjectevaluation
dc.subjectx-ray equipment
dc.subjectmonte carlo method
dc.subjectconversion
dc.subjectdoses
dc.subjectradiation doses
dc.subjectchest
dc.subjectabdomen
dc.titleEvaluation of medical exposure and exposure by the public in a typical scenario of examinations using mobile X-ray equipment through the Monte Carlo simulationpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorWILLIAM S. SANTOS
ipen.codigoautor11952
ipen.contributor.ipenauthorWILLIAM S. SANTOS
ipen.date.recebimento16-09pt_BR
ipen.identifier.fi1.442pt_BR
ipen.identifier.ipendoc22508pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.range.percentilfi75.00 - 100.00
ipen.type.genreArtigo
relation.isAuthorOfPublication8a934cbb-80a1-48d9-a6a3-5b724fbf1e27
relation.isAuthorOfPublication.latestForDiscovery8a934cbb-80a1-48d9-a6a3-5b724fbf1e27
sigepi.autor.atividadeSANTOS, WILLIAM S.:11952:-1:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
22508.pdf
Tamanho:
566.8 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções