Pressure cell for XPD, XAS and SAXS experiments using synchrotron light

dc.contributor.authorORLANDO, M.T.D.pt_BR
dc.contributor.authorPASSAMAI JUNIOR, J.L.pt_BR
dc.contributor.authorMARTINEZ, L.G.pt_BR
dc.contributor.authorROSSI, J.L.pt_BR
dc.contributor.authorCORREA, H.P.S.pt_BR
dc.contributor.authorGARCIA, F.pt_BR
dc.contributor.authorFERREIRA, F.F.pt_BR
dc.contributor.authorMELO, F.C.L.pt_BR
dc.contributor.authorSOUZA JUNIOR, F.G.pt_BR
dc.coverageNacionalpt_BR
dc.creator.eventoREUNIAO ANUAL DE USUARIOS DO LNLS, 20.pt_BR
dc.date.accessioned2014-11-19T11:33:37Zpt_BR
dc.date.accessioned2014-11-19T14:11:39Zpt_BR
dc.date.accessioned2015-04-01T12:44:45Z
dc.date.available2014-11-19T11:33:37Zpt_BR
dc.date.available2014-11-19T14:11:39Zpt_BR
dc.date.available2015-04-01T12:44:45Z
dc.date.evento22-23 de fevereiro, 2010pt_BR
dc.description.abstractA high pressure CuBe cell with B4C anvil has being developed since 2004 for small- and wide-angle synchrotron x-ray scattering experiments under hydrostatic pressure up to 2GPa, at room temperatures. Recently, an optimized version of this cell was used to measure the pressure effect on structure of Cardanol-Furfural-PAni Green Blend in SAXS beam line at Laborat´orio Nacional de Luz Sincrotron - LNLS - Campinas . This cell has also been applied to investigate solid samples behaviour under external hydrostatic pressure since 2007 at LNLS. Moreover, it might also be used to investigate biological system as lipid-water dispersions without changes in its design. Magnetic field up to 1.6 kGauss can be applied together the hydrostatic pressure in this cell, taken into account there is no magnetic signal from de CuBe, B4C anvil, and CuBe gasket used. Investigations about ReO2 behavior under hydrostatic pressure up to 1.6 GPa were performed at LNLS-XPD and XAFS Synchrotron beam line, and the results revealed to be the ReO2 a good inner gauge pressure for 8keV-13keV energy range. This project has been developed by LNLS, UFES, IPEN/CNEN and IEA/CTA collaboration.
dc.format.extent137pt_BR
dc.identifier.citationORLANDO, M.T.D.; PASSAMAI JUNIOR, J.L.; MARTINEZ, L.G.; ROSSI, J.L.; CORREA, H.P.S.; GARCIA, F.; FERREIRA, F.F.; MELO, F.C.L.; SOUZA JUNIOR, F.G. Pressure cell for XPD, XAS and SAXS experiments using synchrotron light. In: REUNIAO ANUAL DE USUARIOS DO LNLS, 20., 22-23 de fevereiro, 2010, Campinas, SP. <b>Resumos...</b> p. 137. Disponível em: http://repositorio.ipen.br/handle/123456789/21133.
dc.identifier.orcidhttps://orcid.org/0000-0002-8304-9939
dc.identifier.orcidhttps://orcid.org/0000-0001-7707-7821
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/21133pt_BR
dc.local.eventoCampinas, SPpt_BR
dc.rightsopenAccesspt_BR
dc.subjectangular distributionpt_BR
dc.subjectcrystallographypt_BR
dc.subjectsmall angle scatteringpt_BR
dc.subjectstructural chemical analysispt_BR
dc.subjectx radiationpt_BR
dc.subjectx-ray diffractionpt_BR
dc.subjectx-ray emission analysispt_BR
dc.subjectx-ray spectrapt_BR
dc.subjectx-ray spectroscopypt_BR
dc.titlePressure cell for XPD, XAS and SAXS experiments using synchrotron lightpt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorJESUALDO LUIZ ROSSI
ipen.autorLUIS GALLEGO MARTINEZ
ipen.codigoautor502
ipen.codigoautor397
ipen.contributor.ipenauthorJESUALDO LUIZ ROSSI
ipen.contributor.ipenauthorLUIS GALLEGO MARTINEZ
ipen.date.recebimento10-08pt_BR
ipen.event.datapadronizada2010pt_BR
ipen.identifier.ipendoc15605pt_BR
ipen.notas.internasResumospt_BR
ipen.type.genreResumo
relation.isAuthorOfPublicationc30c7f95-0303-41bd-aa41-1fc8c12ec2ab
relation.isAuthorOfPublicationd024d136-878b-4d31-bb7e-c1cb06324cfb
relation.isAuthorOfPublication.latestForDiscoveryd024d136-878b-4d31-bb7e-c1cb06324cfb
sigepi.autor.atividadeMARTINEZ, L.G.:397:730:Npt_BR
sigepi.autor.atividadeROSSI, J.L.:502:730:Npt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
15605.pdf
Tamanho:
556.35 KB
Formato:
Adobe Portable Document Format