MRI study of radiation effect on Fricke gel solutions

dc.contributor.authorGALANTE, A.M.S.pt_BR
dc.contributor.authorCERVANTES, H.J.pt_BR
dc.contributor.authorCAVINATO, C.C.pt_BR
dc.contributor.authorCAMPOS, L.L.pt_BR
dc.contributor.authorRABBANI, S.R.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:43:31Zpt_BR
dc.date.accessioned2014-07-30T11:49:46Z
dc.date.available2014-07-15T13:43:31Zpt_BR
dc.date.available2014-07-30T11:49:46Z
dc.date.issued2008pt_BR
dc.description.abstractThe quality control optimization of medical processes that use ionizing radiation in the treatment of diseases like cancer is a key element for patient safety and success of treatment. The major medical application of radiation is radiotherapy, i.e. the delivery of dose levels to well-defined target tissues of a patient with the purpose of eliminating a disease. The need of an accurate tumour-edge definition with the purpose of preserving healthy surrounding tissue demands rigorous radiation treatment planning. Dosimetric methods are used for dose distribution mapping region of interest to assure that the prescribed dose and the irradiated region are correct. The Fricke gel (FXG) is the main dosimeter that supplies visualization of the three-dimensional (3D) dose distribution. In this work the dosimetric characteristics of the modified Fricke dosimeter produced at the Radiation Metrology Centre of the Institute of Energetic and Nuclear Research (IPEN) such as gel concentration dose response dependence, xylenol orange addition influence, dose response between 5 and 50 Gy and signal stability were evaluated by magnetic resonance imaging (MRI). Using the same gel solution, breast simulators (phantoms) were shaped and absorbed dose distributions were imaged by MRI at the Nuclear Resonance Laboratory of the Physics Institute of Sao Paulo University.
dc.format.extent550-553pt_BR
dc.identifier.citationGALANTE, A.M.S.; CERVANTES, H.J.; CAVINATO, C.C.; CAMPOS, L.L.; RABBANI, S.R. MRI study of radiation effect on Fricke gel solutions. <b>Radiation Measurements</b>, v. 43, p. 550-553, 2008. DOI: <a href="https://dx.doi.org/10.1016/j.radmeas.2007.12.011">10.1016/j.radmeas.2007.12.011</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5037.
dc.identifier.doi10.1016/j.radmeas.2007.12.011
dc.identifier.issn1350-4487pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5037pt_BR
dc.identifier.vol43pt_BR
dc.relation.ispartofRadiation Measurementspt_BR
dc.rightsopenAccessen
dc.subjectcarcinomaspt_BR
dc.subjectdosemeterspt_BR
dc.subjectdosimetrypt_BR
dc.subjectgamma radiationpt_BR
dc.subjectgelspt_BR
dc.subjectirradiationpt_BR
dc.subjectmammary glandspt_BR
dc.subjectnmr imagingpt_BR
dc.subjectoptimizationpt_BR
dc.subjectpatientspt_BR
dc.subjectphantomspt_BR
dc.subjectquality controlpt_BR
dc.subjectradiation dose distributionspt_BR
dc.subjectradiation dosespt_BR
dc.subjectradiotherapypt_BR
dc.subjectsimulatorspt_BR
dc.subjectxylenol orangept_BR
dc.titleMRI study of radiation effect on Fricke gel solutionspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorCHRISTIANNE COBELLO CAVINATO
ipen.autorANA MARIA SISTI GALANTE
ipen.codigoautor1195
ipen.codigoautor3880
ipen.codigoautor2181
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorCHRISTIANNE COBELLO CAVINATO
ipen.contributor.ipenauthorANA MARIA SISTI GALANTE
ipen.date.recebimento09-02pt_BR
ipen.identifier.fi1.267pt_BR
ipen.identifier.ipendoc13169pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication7a92997b-7fa4-4eb0-b8f0-7157368c2158
relation.isAuthorOfPublication52063893-84d2-477e-a6d2-f2714be053b0
relation.isAuthorOfPublication.latestForDiscovery52063893-84d2-477e-a6d2-f2714be053b0
sigepi.autor.atividadeGALANTE, A.M.S.:2181:330:Spt_BR
sigepi.autor.atividadeCAVINATO, C.C.:3880:330:Npt_BR
sigepi.autor.atividadeCAMPOS, L.L.:1195:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
13169.pdf
Tamanho:
350.89 KB
Formato:
Adobe Portable Document Format

Coleções