Characterization of a commercial PIN diode for radiotherapy photon beam dosimetry

dc.contributor.authorSILVA, IANDRA T.
dc.contributor.authorPIERI, KAREN
dc.contributor.authorALBINO, LUCAS D.
dc.contributor.authorFONTANA, THIAGO S.
dc.contributor.authorSANTOS, MATHEUS F. dos
dc.contributor.authorROESLER, ERNESTO
dc.contributor.authorOLIVEIRA, CHARLES N.P.
dc.contributor.authorASFORA, VIVIANE K.
dc.contributor.authorGONCALVES, JOSEMARY A.C.
dc.contributor.authorKHOURY, HELEN J.
dc.contributor.authorBUENO, CARMEN C.
dc.coverageInternacional
dc.date.accessioned2024-06-18T18:13:16Z
dc.date.available2024-06-18T18:13:16Z
dc.date.issued2024
dc.description.abstractThe dosimetric characterization of a commercial diode (BPW-34) was performed using a True Beam accelerator (Varian), with flattening filter (FF) photon beams of 6 and 15 MV and flattening filter free (FFF) of 6 MVFFF. The main performance characteristics, namely dose response, energy and dose rate dependence, field output factor, and percentage depth dose profile (PDD), were compared with those available in the literature and, whenever possible, benchmarked against the Varian Eclipse treatment planning system (TPS) predictions. Regardless of the energy, the results showed that the dose response curves are linear (R2 = 1) with nonlinearity parameters less than 0.1% and 0.3% of repeatability. Furthermore, the average dose rate effect (0.7%) is almost negligible within the range of 20–600 MU/min (6 MV, 15 MV) and 400–1400 MU/min (6 MVFFF). Despite these good results, the charge sensitivity measurements evidenced that the diode response depends slightly on the energy, being within 5% for 6 MV–15 MV. It is important to underline that all these results adhere to the standard radiotherapy dosimetry protocols. Moreover, the general output field factor measurements and the percentage depth dose profiles, which are in excellent agreement with the Eclipse TPS calculations, also demonstrated that the diode BPW-34 is a low-budget alternative radiotherapy photon beam dosimeter.
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipFundação de Amparo a Ciência e Tecnologia do Estado de Pernambuco (FACEPE)
dc.description.sponsorshipIDCNPq: INCT-INAIS 406303/2022-3
dc.description.sponsorshipIDFACEPE: APQ-0648-3.09/14
dc.format.extent1-7
dc.identifier.citationSILVA, IANDRA T.; PIERI, KAREN; ALBINO, LUCAS D.; FONTANA, THIAGO S.; SANTOS, MATHEUS F. dos; ROESLER, ERNESTO; OLIVEIRA, CHARLES N.P.; ASFORA, VIVIANE K.; GONCALVES, JOSEMARY A.C.; KHOURY, HELEN J.; BUENO, CARMEN C. Characterization of a commercial PIN diode for radiotherapy photon beam dosimetry. <b>Radiation Physics and Chemistry</b>, v. 221, p. 1-7, 2024. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2024.111772">10.1016/j.radphyschem.2024.111772</a>. Disponível em: https://repositorio.ipen.br/handle/123456789/48135.
dc.identifier.doi10.1016/j.radphyschem.2024.111772
dc.identifier.issn0969-806X
dc.identifier.orcidhttps://orcid.org/0000-0002-8940-9544
dc.identifier.orcidhttps://orcid.org/0000-0001-7881-7254
dc.identifier.percentilfi69.2
dc.identifier.percentilfiCiteScore81.00
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/48135
dc.identifier.vol221
dc.relation.ispartofRadiation Physics and Chemistry
dc.rightsopenAccess
dc.sourceInternational Conference on Dosimetry and its Applications, 4th, October 16-20, 2023, Valencia, Spain
dc.subjectphotons
dc.subjectdosimetry
dc.subjectsilicon
dc.subjectphotodiodes
dc.subjectquality assurance
dc.subjectradiotherapy
dc.titleCharacterization of a commercial PIN diode for radiotherapy photon beam dosimetry
dc.typeArtigo de periódico
dspace.entity.typePublication
ipen.autorJOSEMARY ANGELICA CORREA GONCALVES
ipen.autorCARMEN CECILIA BUENO TOBIAS
ipen.codigoautor924
ipen.codigoautor1592
ipen.contributor.ipenauthorJOSEMARY ANGELICA CORREA GONCALVES
ipen.contributor.ipenauthorCARMEN CECILIA BUENO TOBIAS
ipen.identifier.fi2.8
ipen.identifier.fiCiteScore5.6
ipen.identifier.ipendoc30437
ipen.identifier.iwosWoS
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication76fdc4d1-7624-4332-a9d0-f06826000679
relation.isAuthorOfPublicationfa74399b-83a0-4f46-91e0-da469104d3f6
relation.isAuthorOfPublication.latestForDiscovery76fdc4d1-7624-4332-a9d0-f06826000679
sigepi.autor.atividadeJOSEMARY ANGELICA CORREA GONCALVES:924:240:N
sigepi.autor.atividadeCARMEN CECILIA BUENO TOBIAS:1592:240:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
30437.pdf
Tamanho:
3.64 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções