Tandem KAP meters calibration parameters by Monte Carlo Simulation using reference RQR radiation qualities

Carregando...
Imagem de Miniatura

Data

Data de publicação

2016

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

É parte de

INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 14th
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
The Kerma-area product quantity can be obtained by measurements carried out with a kerma-area product meter (KAP) with a plane-parallel transmission ionization chamber mounted on the X ray system. It is the integral of the air kerma over the area of the X ray beam in a plane perpendicular to the beam axis. This quantity has been important to establish the diagnostic reference levels (DRLs) all over the word. In this work the MCNP5 code was used to calculate the imparted energy in the air cavity of KAP meter and the spatial distribution of the air collision kerma in entrance plan of the KAP meter. From these data, the air kerma-area product (KAP) and the calibration coefficient for the KAP meter were calculated and compared with those obtained experimentally. The X-ray tube was easily modelled as well the complete tandem calibration set up was possible. The spectra of the diagnostic radiology RQR reference qualities measured were used as a source definition in the input card for the Monte Carlo simulation. The clinical KAP meter calibration coefficients were obtained experimentally and by Monte Carlo simulation. The differences between those values were about 2%, except for RQR 10 (5.45%). The uncertainties in Monte Carlo simulation were less than 0.5% in all cases and the FOM (Figure of Merit) was constant for a number of histories of 1 million.

Como referenciar
POTIENS JUNIOR, ADEMAR; COSTA, NATHALIA; CORREA, EDUARDO; SANTOS, LUCAS; VIVOLO, VITOR; POTIENS, MARIA da P. Tandem KAP meters calibration parameters by Monte Carlo Simulation using reference RQR radiation qualities. In: CLEMENT, CHRISTOPHER (ed.); VALENTIN, JACK (ed.); OGINO, HARUYUKI (ed.); FOOTE, DEVON (ed.); REYJAL, JULIE (ed.); OMAR-NAZIR, LAILA (ed.). In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 14th, May 9-13, 2016, Cape Town, South Africa. Abstract... p. 702-702. Disponível em: http://repositorio.ipen.br/handle/123456789/31268. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento