Use of amperometric and potentiometric probes in scanning electrochemical microscopy for the spatially-resolved monitoring of severe localized corrosion sites on aluminum alloy 2098-T351
| dc.contributor.author | SILVA, REJANE M.P. da | pt_BR |
| dc.contributor.author | IZQUIERDO, JAVIER | pt_BR |
| dc.contributor.author | MILAGRE, MARIANA X. | pt_BR |
| dc.contributor.author | BETANCOR-ABREU, ABENCHARA M. | pt_BR |
| dc.contributor.author | COSTA, ISOLDA | pt_BR |
| dc.contributor.author | SOUTO, RICARDO M. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2021-07-26T18:36:00Z | |
| dc.date.available | 2021-07-26T18:36:00Z | |
| dc.date.issued | 2021 | pt_BR |
| dc.description.abstract | Amperometric and potentiometric probes were employed for the detection and characterization of reactive sites on the 2098-T351 Al-alloy (AA2098-T351) using scanning electrochemical microscopy (SECM). Firstly, the probe of concept was performed on a model Mg-Al galvanic pair system using SECM in the amperometric and potentiometric operation modes, in order to address the responsiveness of the probes for the characterization of this galvanic pair system. Next, these sensing probes were employed to characterize the 2098-T351 alloy surface immersed in a saline aqueous solution at ambient temperature. The distribution of reactive sites and the local pH changes associated with severe localized corrosion (SLC) on the alloy surface were imaged and subsequently studied. Higher hydrogen evolution, lower oxygen depletion and acidification occurred at the SLC sites developed on the 2098-T351 Al-alloy. | pt_BR |
| dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | pt_BR |
| dc.description.sponsorshipID | FAPESP: 13/13235-6; 18/06880-6; 19/11427-1 | pt_BR |
| dc.format.extent | 1-15 | pt_BR |
| dc.identifier.citation | SILVA, REJANE M.P. da; IZQUIERDO, JAVIER; MILAGRE, MARIANA X.; BETANCOR-ABREU, ABENCHARA M.; COSTA, ISOLDA; SOUTO, RICARDO M. Use of amperometric and potentiometric probes in scanning electrochemical microscopy for the spatially-resolved monitoring of severe localized corrosion sites on aluminum alloy 2098-T351. <b>Sensors</b>, v. 21, n. 4, p. 1-15, 2021. DOI: <a href="https://dx.doi.org/10.3390/s21041132">10.3390/s21041132</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/32058. | |
| dc.identifier.doi | 10.3390/s21041132 | pt_BR |
| dc.identifier.fasciculo | 4 | pt_BR |
| dc.identifier.issn | 1424-8220 | pt_BR |
| dc.identifier.orcid | 0000-0002-4987-3334 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-4987-3334 | |
| dc.identifier.percentilfi | 68.03 | pt_BR |
| dc.identifier.percentilfiCiteScore | 79.00 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/32058 | |
| dc.identifier.vol | 21 | pt_BR |
| dc.relation.ispartof | Sensors | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | aluminium alloys | |
| dc.subject | corrosion | |
| dc.subject | electrochemical corrosion | |
| dc.subject | amperometry | |
| dc.subject | probes | |
| dc.subject | measuring instruments | |
| dc.title | Use of amperometric and potentiometric probes in scanning electrochemical microscopy for the spatially-resolved monitoring of severe localized corrosion sites on aluminum alloy 2098-T351 | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | MARIANA XAVIER MILAGRE | |
| ipen.autor | ISOLDA COSTA | |
| ipen.autor | REJANE MARIA PEREIRA DA SILVA | |
| ipen.codigoautor | 12144 | |
| ipen.codigoautor | 429 | |
| ipen.codigoautor | 14978 | |
| ipen.contributor.ipenauthor | MARIANA XAVIER MILAGRE | |
| ipen.contributor.ipenauthor | ISOLDA COSTA | |
| ipen.contributor.ipenauthor | REJANE MARIA PEREIRA DA SILVA | |
| ipen.date.recebimento | 21-07 | |
| ipen.identifier.fi | 3.847 | pt_BR |
| ipen.identifier.fiCiteScore | 6.4 | |
| ipen.identifier.ipendoc | 27829 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.identifier.ods | 7 | |
| ipen.range.fi | 3.000 - 4.499 | |
| ipen.range.percentilfi | 50.00 - 74.99 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 168f0b7a-8247-4b71-b3a3-c73d18ae3f25 | |
| relation.isAuthorOfPublication | 952cc9fe-41a5-443f-b21a-316edc344ec8 | |
| relation.isAuthorOfPublication | 3ef8cd3e-aa90-4e70-8643-05e296d459ae | |
| relation.isAuthorOfPublication.latestForDiscovery | 3ef8cd3e-aa90-4e70-8643-05e296d459ae | |
| sigepi.autor.atividade | COSTA, ISOLDA:429:730:N | pt_BR |
| sigepi.autor.atividade | MILAGRE, MARIANA X.:12144:730:N | pt_BR |
| sigepi.autor.atividade | SILVA, REJANE M.P. da:14978:730:S | pt_BR |