Performance of GEANT4 in dosimetry applications: calculation of X-ray spectra and kerma-to-dose equivalent conversion coefficients

dc.contributor.authorGUIMARAES, CARLA C.pt_BR
dc.contributor.authorMORALLES, MAURICIOpt_BR
dc.contributor.authorOKUNO, EMICOpt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:43:07Zpt_BR
dc.date.accessioned2014-07-30T11:49:58Z
dc.date.available2014-07-15T13:43:07Zpt_BR
dc.date.available2014-07-30T11:49:58Z
dc.date.issued2008pt_BR
dc.description.abstractIn order to validate the Geant4 toolkit for dosimetry applications, simulations were performed to calculate conversion coefficients h(10, a) from air kerma free-in-air to personal dose equivalent Hp(10, a). The simulations consisted of two parts: the production of X-rays with radiation qualities of narrow and wide spectra, and the interaction of radiation with ICRU tissue-equivalent and ISO water slab phantoms. The half-value layers of the X-ray spectra obtained by simulation were compared with experimental results. Mean energy, spectral resolution, half-value layers and conversion coefficients were compared with ISO reference values. The good agreement between results from simulation and reference data shows that the Geant4 is suitable for dosimetry applications which involve photons with energies in the range of ten to a few hundreds of keV
dc.format.extent1525-1531pt_BR
dc.identifier.citationGUIMARAES, CARLA C.; MORALLES, MAURICIO; OKUNO, EMICO. Performance of GEANT4 in dosimetry applications: calculation of X-ray spectra and kerma-to-dose equivalent conversion coefficients. <b>Radiation Measurements</b>, v. 43, n. 9-10, p. 1525-1531, 2008. DOI: <a href="https://dx.doi.org/10.1016/j.radmeas.2008.07.001">10.1016/j.radmeas.2008.07.001</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/4999.
dc.identifier.doi10.1016/j.radmeas.2008.07.001
dc.identifier.fasciculo9-10pt_BR
dc.identifier.issn1350-4487pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-2664-5531
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/4999pt_BR
dc.identifier.vol43pt_BR
dc.relation.ispartofRadiation Measurementspt_BR
dc.rightsopenAccessen
dc.subjectmonte carlo methodpt_BR
dc.subjectg codespt_BR
dc.subjectsimulationpt_BR
dc.subjectdose equivalentspt_BR
dc.subjectdosimetrypt_BR
dc.subjectphantomspt_BR
dc.titlePerformance of GEANT4 in dosimetry applications: calculation of X-ray spectra and kerma-to-dose equivalent conversion coefficientspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMAURICIO MORALLES
ipen.codigoautor923
ipen.contributor.ipenauthorMAURICIO MORALLES
ipen.date.recebimento09-05pt_BR
ipen.identifier.fi1.267pt_BR
ipen.identifier.ipendoc13725pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublicationdc9e7d8e-c880-41f7-971e-b300272b6750
relation.isAuthorOfPublication.latestForDiscoverydc9e7d8e-c880-41f7-971e-b300272b6750
sigepi.autor.atividadeMORALLES, MAURICIO:923:310:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
13725.pdf
Tamanho:
443.98 KB
Formato:
Adobe Portable Document Format

Coleções