GEANT4 simulation of the angular dependence of TLD based monitor response

dc.contributor.authorGUIMARAES, C.C.pt_BR
dc.contributor.authorMORALLES, M.pt_BR
dc.contributor.authorOKUNO, E.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 10thpt_BR
dc.date.accessioned2014-11-19T10:59:56Zpt_BR
dc.date.accessioned2014-11-19T14:03:49Zpt_BR
dc.date.accessioned2015-04-01T13:54:32Z
dc.date.available2014-11-19T10:59:56Zpt_BR
dc.date.available2014-11-19T14:03:49Zpt_BR
dc.date.available2015-04-01T13:54:32Z
dc.date.eventoSeptember 17-22, 2006pt_BR
dc.description.abstractIn this work the response of thermoluminescent monitors to X-ray beams impinging on them at different angles was investigated and compared with results of simulations performed with the GEANT4 radiation transport toolkit. Each monitor contains four thermoluminescent detectors (TLD): two CaF2 pellets and two TLD-100 (one of each type within lead filter and the other without filter). This set of detectors allows the determination of photon energy. Monitors were irradiated free-in-air with beams of narrow and wide spectra with effective energies of 34, 61 and 130 keV and angles of incidence of 0°, 30°, 45° and 60° using a X-ray Philips MG-450 tube. Curves of thermoluminescence response relative to air kerma as a function of photon effective energy for each detector experimentally obtained are used to correct the energetic dependence of TL response. Such curves were also obtained from the data of radiation energy stored into the TLDs provided by the simulations. The differences between experimental results and the Monte Carlo simulations indicate that the dose distribution is strongly affected by the thickness of lead filter, which attenuates the intensity of radiation incident on the monitor. The attenuation increases with the increase of the incidence angle, since the thickness of lead traversed by the beam also increases. As the monitor calibration is usually performed with the beams impinging the monitor at 0°, changes in the attenuation become a source of error in the energy determination and consequently in the value of dose equivalent which is obtained with this monitor. Correction factors to compensate this effect can be evaluated with Monte Carlo simulations.
dc.event.siglaISRP10pt_BR
dc.format.extentD-34pt_BR
dc.identifier.citationGUIMARAES, C.C.; MORALLES, M.; OKUNO, E. GEANT4 simulation of the angular dependence of TLD based monitor response. In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 10th, September 17-22, 2006, Coimbra, Portugal. <b>Abstract...</b> p. D-34. Disponível em: http://repositorio.ipen.br/handle/123456789/20401.
dc.identifier.orcidhttps://orcid.org/0000-0002-2664-5531
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/20401pt_BR
dc.local.eventoCoimbra, Portugalpt_BR
dc.rightsopenAccesspt_BR
dc.subjectthermoluminescencept_BR
dc.subjectthermoluminescent dosimetrypt_BR
dc.subjectradiation monitorspt_BR
dc.subjectmonte carlo methodpt_BR
dc.subjectsimulationpt_BR
dc.titleGEANT4 simulation of the angular dependence of TLD based monitor responsept_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorMAURICIO MORALLES
ipen.codigoautor923
ipen.contributor.ipenauthorMAURICIO MORALLES
ipen.date.recebimento10-08pt_BR
ipen.event.datapadronizada2006pt_BR
ipen.identifier.ipendoc15531pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublicationdc9e7d8e-c880-41f7-971e-b300272b6750
relation.isAuthorOfPublication.latestForDiscoverydc9e7d8e-c880-41f7-971e-b300272b6750
sigepi.autor.atividadeMORALLES, M.:923:6:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
15531.pdf
Tamanho:
12.77 KB
Formato:
Adobe Portable Document Format