Monte Carlo simulation of a position sensitive gamma ray detector

dc.contributor.authorALMEIDA, M.pt_BR
dc.contributor.authorMORALLES, M.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:48:57Zpt_BR
dc.date.accessioned2014-07-30T11:46:28Z
dc.date.available2014-07-15T13:48:57Zpt_BR
dc.date.available2014-07-30T11:46:28Z
dc.date.issued2005pt_BR
dc.description.abstractThe Monte Carlo method was employed to obtain the response of a position sensitive gamma ray detector. The basic unit consists of a scintillator bar coupled to two photon detectors. Determination of the position of interaction is obtained from the ratio of the light intensity measured at each extremity of the bar. Association of two or more detectors of this type can be used to build a system with potential use in positron emission tomography. For practical purposes, a CsI(Tl) bar with dimensions of 15×1×1 \thinspacecm³ was considered. Simulations were performed with the GEANT4 toolkit, using the physical processes of low-energy electromagnetic extension. Light attenuation coefficient and energy resolution of CsI(Tl) bars were included according to data found in the literature. Results obtained from detector irradiation with 511 keV annihilation photons indicate that the position of interaction can be determined with uncertainty of 3 mm. Simulations of positron sources placed between two detectors were also performed and two dimensional images were obtained.
dc.format.extent741-743pt_BR
dc.identifier.citationALMEIDA, M.; MORALLES, M. Monte Carlo simulation of a position sensitive gamma ray detector. <b>Brazilian Journal of Physics</b>, v. 35, n. 3B, p. 741-743, 2005. DOI: <a href="https://dx.doi.org/10.1590/S0103-97332005000500004">10.1590/S0103-97332005000500004</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5514.
dc.identifier.doi10.1590/S0103-97332005000500004
dc.identifier.fasciculo3Bpt_BR
dc.identifier.issn0103-9733pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-2664-5531
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5514pt_BR
dc.identifier.vol35pt_BR
dc.relation.ispartofBrazilian Journal of Physicspt_BR
dc.rightsopenAccessen
dc.subjectpositron computed tomographypt_BR
dc.subjectscintillation counterspt_BR
dc.subjectphotodiodespt_BR
dc.subjectcomputerized simulationpt_BR
dc.subjectmonte carlo methodpt_BR
dc.subjectgamma detectionpt_BR
dc.subjectnuclear medicinept_BR
dc.titleMonte Carlo simulation of a position sensitive gamma ray detectorpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMAURICIO MORALLES
ipen.autorMARCELO DE ALMEIDA
ipen.codigoautor923
ipen.codigoautor3267
ipen.contributor.ipenauthorMAURICIO MORALLES
ipen.contributor.ipenauthorMARCELO DE ALMEIDA
ipen.date.recebimento06-01pt_BR
ipen.identifier.fi0.445pt_BR
ipen.identifier.ipendoc11168pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublicationdc9e7d8e-c880-41f7-971e-b300272b6750
relation.isAuthorOfPublication5d8516bf-b0c3-40b2-b1b0-0f7a1dfa64ba
relation.isAuthorOfPublication.latestForDiscovery5d8516bf-b0c3-40b2-b1b0-0f7a1dfa64ba
sigepi.autor.atividadeALMEIDA, M.:3267:6:Spt_BR
sigepi.autor.atividadeMORALLES, M.:923:6:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
11168.pdf
Tamanho:
128.64 KB
Formato:
Adobe Portable Document Format

Coleções