Characterization of an extrapolation chamber in beta radiation beams and Monte Carlo modelling

dc.contributor.authorPOLO, IVON O.pt_BR
dc.contributor.authorSANTOS, WILLIAM S.pt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2020-10-13T14:16:31Z
dc.date.available2020-10-13T14:16:31Z
dc.date.issued2020pt_BR
dc.description.abstractAt the Calibration Laboratory (LCI) of the IPEN/CNEN, studies are in development on the establishment of a standard composed by the beta radiation sources for the dosimetry and calibration for personal monitoring in Brazil. For this purpose is used the Böhm extrapolation chamber (PTW model 23392). This chamber was already characterized at LCI in 90Sr/90Y beams using two different entrance windows: one of aluminized Mylar and another of PET (polyethylene terephthalate) known as Hostaphan. In this work, this extrapolation chamber was characterized in 85Kr and 147Pm beams. All tests were carried out with the reference 90Sr /90Y source, for comparison purposes. The Monte Carlo code MCNP5 code was used to obtain an extrapolation chamber and the BSS2 system sources computational model, based on the determination of the absorbed dose rate. Saturation curves, ion collection efficiency, ion recombination, polarity effect, stability of response, null depth, linearity of response, variation of response as a function of source-detector distance, extrapolation curves, correction factors and absorbed dose rates were obtained. The difference between the experimental absorbed dose rates and those obtained using the Monte Carlo model, compared to those from the calibration certificates, was less than 1.9% for the 108 histories for each BSS2 system source. All results of the performed tests are within the limits of the international recommendations. The results for the 90Sr/90Y source were in good agreement with previous works performed at LCI. These results are suitable for the establishment of a standard instrument for the dosimetry and calibration of beta radiation sources and detectors in the LCI/IPEN. This standard will allow the calibration of detectors in beta radiation beams in dosimetry services in Brazil.pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipIDCNPq: 142297/2015-1; 301335/2016-8pt_BR
dc.description.sponsorshipIDCAPES: 554/2018pt_BR
dc.format.extent1-9pt_BR
dc.identifier.citationPOLO, IVON O.; SANTOS, WILLIAM S.; CALDAS, LINDA V.E. Characterization of an extrapolation chamber in beta radiation beams and Monte Carlo modelling. <b>Radiation Physics and Chemistry</b>, v. 171, p. 1-9, 2020. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2020.108746">10.1016/j.radphyschem.2020.108746</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/31423.
dc.identifier.doi10.1016/j.radphyschem.2020.108746pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.percentilfi66.43pt_BR
dc.identifier.percentilfiCiteScore72.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/31423
dc.identifier.vol171pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.sourceInternational Conference on Dosimetry and its Applications, 3rd, May 27-31, 2019, Lisbon, Portugalpt_BR
dc.subjectextrapolation chambers
dc.subjectradiation doses
dc.subjectbeta sources
dc.subjectmonte carlo method
dc.subjectcalibration
dc.subjectcalibration standards
dc.subjectlaboratories
dc.titleCharacterization of an extrapolation chamber in beta radiation beams and Monte Carlo modellingpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorWILLIAM DE SOUZA SANTOS
ipen.autorLINDA V. E. CALDAS
ipen.autorIVON ORAMAS POLO
ipen.codigoautor12113
ipen.codigoautor1495
ipen.codigoautor14120
ipen.contributor.ipenauthorWILLIAM DE SOUZA SANTOS
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorIVON ORAMAS POLO
ipen.date.recebimento20-10
ipen.identifier.fi2.858pt_BR
ipen.identifier.fiCiteScore3.8
ipen.identifier.ipendoc27197pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublicatione60e87cd-ba27-4148-a906-95e6cefff669
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication685f842c-100e-4c4e-ad40-d73c77cc2a75
relation.isAuthorOfPublication.latestForDiscovery685f842c-100e-4c4e-ad40-d73c77cc2a75
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR
sigepi.autor.atividadeSANTOS, WILLIAM S.:12113:330:Npt_BR
sigepi.autor.atividadePOLO, IVON O.:14120:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27197.pdf
Tamanho:
1.43 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções