In vitro flexural strength evaluation of a mini-implant prototype designed for Herbst appliance anchorage
| dc.contributor.author | BARRETO-LOPES, KLAUS | |
| dc.contributor.author | DOMINGUEZ, GLADYS C. | |
| dc.contributor.author | TORTAMANO, ANDRE | |
| dc.contributor.author | ROSSI, JESUALDO L. | |
| dc.contributor.author | VIGORITO, JULIO W. | |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2016-11-10T13:01:21Z | |
| dc.date.available | 2016-11-10T13:01:21Z | |
| dc.date.issued | 2010 | pt_BR |
| dc.description.abstract | Aim: The purpose of this study was to evaluate the limit of flexural strength of a miniimplant prototype designed for Herbst appliance anchorage. Methods: After sample size calculation, four specimens with the new mini-implant were submitted to a single cantilever flexure test using a universal testing machine. The limit of flexural force strength was calculated. Results: The mini-implant prototype showed a limit of flexural force strength of 98.2 kgf (982 N), that was the lowest value found. Conclusion: The mini-implant prototype designed for Herbst appliance anchorage can withstand flexural forces higher than the maximum human bite forces reported in the literature. | pt_BR |
| dc.format.extent | 38.e1-38.e6 | pt_BR |
| dc.identifier.citation | BARRETO-LOPES, KLAUS; DOMINGUEZ, GLADYS C.; TORTAMANO, ANDRE; ROSSI, JESUALDO L.; VIGORITO, JULIO W. In vitro flexural strength evaluation of a mini-implant prototype designed for Herbst appliance anchorage. <b>Dental Press Journal of Orthodontics</b>, v. 15, n. 4, p. 38.e1-38.e6, 2010. DOI: <a href="https://dx.doi.org/10.1590/S2176-94512010000400006">10.1590/S2176-94512010000400006</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/26777. | |
| dc.identifier.doi | 10.1590/S2176-94512010000400006 | pt_BR |
| dc.identifier.fasciculo | 4 | pt_BR |
| dc.identifier.issn | 2176-9451 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-8304-9939 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/26777 | |
| dc.identifier.vol | 15 | pt_BR |
| dc.relation.ispartof | Dental Press Journal of Orthodontics | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | oral cavity | |
| dc.subject | dentistry | |
| dc.subject | implants | |
| dc.subject | brass | |
| dc.subject | channeling | |
| dc.title | In vitro flexural strength evaluation of a mini-implant prototype designed for Herbst appliance anchorage | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | JESUALDO LUIZ ROSSI | |
| ipen.codigoautor | 502 | |
| ipen.contributor.ipenauthor | JESUALDO LUIZ ROSSI | |
| ipen.date.recebimento | 16-11 | pt_BR |
| ipen.identifier.fi | Sem F.I. | pt_BR |
| ipen.identifier.ipendoc | 22649 | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | c30c7f95-0303-41bd-aa41-1fc8c12ec2ab | |
| relation.isAuthorOfPublication.latestForDiscovery | c30c7f95-0303-41bd-aa41-1fc8c12ec2ab | |
| sigepi.autor.atividade | ROSSI, JESUALDO L.:502:730:N | pt_BR |