Characterization of neutron spectrum at the short irradiation facility of the IEA-R1 reactor using the bare triple monitor method
dc.contributor.author | FLORES, J.P.O. | |
dc.contributor.author | SEMMLER, R. | |
dc.coverage | Internacional | pt_BR |
dc.creator.evento | 60 YEARS OF IEA-R1: INTERNATIONAL WORKSHOP ON UTILIZATION OF RESEARCH REACTORS | pt_BR |
dc.date.accessioned | 2018-03-15T11:44:17Z | |
dc.date.available | 2018-03-15T11:44:17Z | |
dc.date.evento | November 28 - December 01, 2017 | pt_BR |
dc.description.abstract | The neutron spectrum parameters were determined in the short irradiation facility of the IEA-R1 reactor of IPEN. The neutron spectrum parameters are: the epithermal neutron flux shape factor ( ) approximated by a 1=E1+ distribution and the thermal to epithermal neutron flux ratio (f ). According to the HOGDAHL formalism, the k0-NAA method uses the following input parameters: the full energy peak detection efficiency ("p), and nuclear data on Q0 (ratio of resonance integral I0 to thermal neutron cross-section 0) and k0 factors. The and f parameters depend on each irradiation facility and "p depends on each counting facility. In the HOGDAHL formalism the reactor neutron spectrum parameters ( and f ) can be obtained using three methods: Cd-ratio, Cd-covered and bare triple monitors. In this work and f were determined by the bare triple monitor method. In this method, a set of three neutron flux monitors are irradiated without Cd-cover. The efficiency curves of the gamma-ray spectrometer used were determined by measuring calibrated radioactive sources at the usually utilized counting geometries. | pt_BR |
dc.format.extent | 30-30 | pt_BR |
dc.identifier.citation | FLORES, J.P.O.; SEMMLER, R. Characterization of neutron spectrum at the short irradiation facility of the IEA-R1 reactor using the bare triple monitor method. In: 60 YEARS OF IEA-R1: INTERNATIONAL WORKSHOP ON UTILIZATION OF RESEARCH REACTORS, November 28 - December 01, 2017, São Paulo, SP. <b>Abstract...</b> São Paulo, SP: Instituto de Pesquisas Energéticas e Nucleares, 2017. p. 30-30. Disponível em: http://repositorio.ipen.br/handle/123456789/28725. | |
dc.identifier.orcid | https://orcid.org/0000-0001-7733-0153 | |
dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/28725 | |
dc.local | São Paulo, SP | pt_BR |
dc.local.evento | São Paulo, SP | pt_BR |
dc.publisher | Instituto de Pesquisas Energéticas e Nucleares | pt_BR |
dc.rights | openAccess | pt_BR |
dc.title | Characterization of neutron spectrum at the short irradiation facility of the IEA-R1 reactor using the bare triple monitor method | pt_BR |
dc.type | Resumo de eventos científicos | pt_BR |
dspace.entity.type | Publication | |
ipen.autor | RENATO SEMMLER | |
ipen.autor | JOAO PEDRO DE OLIVEIRA FLORES | |
ipen.codigoautor | 833 | |
ipen.codigoautor | 10625 | |
ipen.contributor.ipenauthor | RENATO SEMMLER | |
ipen.contributor.ipenauthor | JOAO PEDRO DE OLIVEIRA FLORES | |
ipen.date.recebimento | 18-03 | pt_BR |
ipen.event.datapadronizada | 2017 | pt_BR |
ipen.identifier.ipendoc | 24547 | pt_BR |
ipen.notas.internas | Abstract | pt_BR |
ipen.type.genre | Resumo | |
relation.isAuthorOfPublication | f95a9324-04eb-409b-86b2-97eaa10134f2 | |
relation.isAuthorOfPublication | c5e02eba-4be0-4bc3-8e21-1cbf697b3a55 | |
relation.isAuthorOfPublication.latestForDiscovery | c5e02eba-4be0-4bc3-8e21-1cbf697b3a55 | |
sigepi.autor.atividade | FLORES, J.P.O.:10625:310:S | pt_BR |
sigepi.autor.atividade | SEMMLER, R.:833:310:N | pt_BR |