Commercial filament testing for use in 3D printed phantoms

dc.contributor.authorSAVI, MATHEUSpt_BR
dc.contributor.authorANDRADE, MARCO A.B.pt_BR
dc.contributor.authorPOTIENS, MARIA P.A.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2020-10-13T14:33:06Z
dc.date.available2020-10-13T14:33:06Z
dc.date.issued2020pt_BR
dc.description.abstractThere is a great demand for phantoms by many areas of knowledge to be used for teaching or daily work. However, commercial phantoms are expensive and hard to obtain, especially in countries going through development. As an alternative, 3D printing can be the way to produce less expensive and reliable 3D phantoms. The goal of this study is to evaluate 14 available commercial filaments, in order to find if and how they can be used in 3D printed phantoms in computed tomography. Each material was printed as a 2 cm edge cube with rectilinear pattern and 60, 80 and 100% infill. The 80% infill of five other patterns were also printed and compared. Each 100% infill cube was weighted and had its density calculated. After that, the cubes were scanned in a Philips CT Brilliance 6 with 120 kVp, 200 mA, 2 mm slices and standard reconstruction. At the center of each cube, a ~120 mm2 region of interest was set to measure the mean Hounsfield Unit (HU) and its standard deviation. The software Origin was used to plot HU results for rectilinear pattern, determine linear trends with its R2 and compare achieved values with HU tissue range from literature. To confirm the response of HU values of selected tested materials in CT imaging as a function of percentage infill, a phantom prototype of a finger was 3D printed. The HU of the tested materials ranged from −516.2 ± 7.3 to 329.8 ± 18.9. All human tissues could be mimicked making use of these materials, except cortical bone above ~350 HU and tooth parts. The most promising filament was PLA + Cu, due to the multiple infill configuration that allows the resulting HU range to represent from adipose and skin tissue to marrow bone.pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipIDCAPES: 554/2018pt_BR
dc.description.sponsorshipIDFAPESP: 17/50332-0pt_BR
dc.description.sponsorshipIDCNPq: 312131/2016-0pt_BR
dc.format.extent1-7pt_BR
dc.identifier.citationSAVI, MATHEUS; ANDRADE, MARCO A.B.; POTIENS, MARIA P.A. Commercial filament testing for use in 3D printed phantoms. <b>Radiation Physics and Chemistry</b>, v. 174, p. 1-7, 2020. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2020.108906">10.1016/j.radphyschem.2020.108906</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/31424.
dc.identifier.doi10.1016/j.radphyschem.2020.108906pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.orcid0000-0002-4049-6720pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.percentilfi66.43pt_BR
dc.identifier.percentilfiCiteScore72.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/31424
dc.identifier.vol174pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.sourceInternational Conference on Dosimetry and its Applications, 3rd, May 27-31, 2019, Lisbon, Portugalpt_BR
dc.subject3d printing
dc.subjectphantoms
dc.subjectfabrication
dc.subjectfilaments
dc.subjectradiology
dc.subjectcomputerized tomography
dc.titleCommercial filament testing for use in 3D printed phantomspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorMATHEUS BRUM MARQUES BIANCHI SAVI
ipen.codigoautor346
ipen.codigoautor14908
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorMATHEUS BRUM MARQUES BIANCHI SAVI
ipen.date.recebimento20-10
ipen.identifier.fi2.858pt_BR
ipen.identifier.fiCiteScore3.8
ipen.identifier.ipendoc27198pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublicationdd5258bb-520a-4996-8be7-515ae5609ed7
relation.isAuthorOfPublication.latestForDiscoverydd5258bb-520a-4996-8be7-515ae5609ed7
sigepi.autor.atividadePOTIENS, MARIA P.A.:346:330:Npt_BR
sigepi.autor.atividadeSAVI, MATHEUS:14908:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27198.pdf
Tamanho:
1.11 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções