Using the optically stimulated luminescence technique for one- and two-dimensional dose mapping

dc.contributor.authorGASPARIAN, PATRICIA B.R.pt_BR
dc.contributor.authorMALTHEZ, ANNA L.M.C.pt_BR
dc.contributor.authorCAMPOS, LETICIA L.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2022-12-16T12:13:40Z
dc.date.available2022-12-16T12:13:40Z
dc.date.issued2022pt_BR
dc.description.abstractIn respect of radiation dosimetry, several applications require dose distribution verification rather than absolute dosimetry. Most protocols use radiological and radiochromic films and ionization chambers or diode arrays for dose mapping. The films are disposable which causes the precision of the results dependent on film production variability. The measurements with arrays of ionization chambers or diodes mainly lack spatial resolution. This review aims to provide an overview of the use of optically stimulated luminescence detectors (OSLDs) for one-dimensional (1D) and two-dimensional (2D) dose mapping in different applications. It reviews the ideas, OSL materials, and applications related to the assessment of dose distribution using OSLDs in the form of film or ceramic plate (BeO). Additionally, it reviews research published in the international scientific literature from 1998 to 2021. As an outcome, a table containing the main characteristics of each relevant paper is shown. The results section was divided by the type of OSL material, and we briefly described the principal findings and the significant developments of each mentioned study such as film production and OSL reader assembly. The purpose of this study was to present an overview of the main findings of several research groups on the use of OSLD in the form of film or plate for 1D and 2D dose mapping. Finally, the potential future development of dose mapping using OSLD films was outlined.pt_BR
dc.format.extent1-15pt_BR
dc.identifier.citationGASPARIAN, PATRICIA B.R.; MALTHEZ, ANNA L.M.C.; CAMPOS, LETICIA L. Using the optically stimulated luminescence technique for one- and two-dimensional dose mapping: a brief review. <b>Physics in Medicine and Biology</b>, v. 67, n. 19, p. 1-15, 2022. DOI: <a href="https://dx.doi.org/10.1088/1361-6560/ac9030">10.1088/1361-6560/ac9030</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/33458.
dc.identifier.doi10.1088/1361-6560/ac9030pt_BR
dc.identifier.fasciculo19pt_BR
dc.identifier.issn0031-9155pt_BR
dc.identifier.orcid0000-0001-7137-0613pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.percentilfi59.8pt_BR
dc.identifier.percentilfiCiteScore77pt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/33458
dc.identifier.vol67pt_BR
dc.relation.ispartofPhysics in Medicine and Biologypt_BR
dc.rightsopenAccesspt_BR
dc.subjectluminescent dosemeters
dc.subjectone-dimensional calculations
dc.subjecttwo-dimensional calculations
dc.subjectdosimetry
dc.subjectionization chambers
dc.subjectdose rates
dc.subjectfilms
dc.subjectradiation detection
dc.titleUsing the optically stimulated luminescence technique for one- and two-dimensional dose mappingpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorPATRICIA BERINGHS RIO
ipen.codigoautor1195
ipen.codigoautor7070
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorPATRICIA BERINGHS RIO
ipen.date.recebimento22-12
ipen.identifier.fi3.5pt_BR
ipen.identifier.fiCiteScore6.9pt_BR
ipen.identifier.ipendoc29092pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi3.000 - 4.499
ipen.range.percentilfi50.00 - 74.99
ipen.subtituloa brief reviewpt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication2c6b2429-cea9-4241-b7b3-7b5b20d13443
relation.isAuthorOfPublication.latestForDiscovery2c6b2429-cea9-4241-b7b3-7b5b20d13443
sigepi.autor.atividadeCAMPOS, LETICIA L.:1195:330:Npt_BR
sigepi.autor.atividadeGASPARIAN, PATRICIA B.R.:7070:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
29092.pdf
Tamanho:
833.29 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções