Sodium interference in lithium isotope ratio analysis by Inductively Coupled Plasma Mass Spectrometry

dc.contributor.authorANDRADE, MARIANA N. dept_BR
dc.contributor.authorOTOMO, JULIANA I.pt_BR
dc.contributor.authorGIMENEZ, MAISE P.pt_BR
dc.contributor.authorNASCIMENTO, LETICIA da S.pt_BR
dc.contributor.authorNASCIMENTO, HENRIQUE B. dopt_BR
dc.contributor.authorLEAO, PAULO H.B.pt_BR
dc.contributor.authorCECILIO, PRISCILA de S.pt_BR
dc.contributor.authorFERREIRA, JOAO C.pt_BR
dc.contributor.authorBERGAMASCHI, VANDERLEI S.pt_BR
dc.contributor.authorBUSTILLOS, OSCAR V.pt_BR
dc.contributor.coordenadorSIMIONATO, ANA V.C.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoIBEROAMERICAN CONFERENCE ON MASS SPECTROMETRY, 3rdpt_BR
dc.date.accessioned2023-03-23T19:38:38Z
dc.date.available2023-03-23T19:38:38Z
dc.date.eventoDecember 10-15, 2022pt_BR
dc.description.abstractIntroduction: Naturally occurring lithium consists of two stable isotopes, 6Li (7.591%) and 7Li (92.409%) and have applications in nuclear technology, pharmaceutical, automotive and geological research. Enriched 7Li isotope in LiOH form has been used as a pH regulator for Pressurized Water Reactor (PWR) reducing corrosion in the primary water circuit [1-3]. The determination of lithium isotopic composition was analyzed by Inductively Coupled Plasma Mass Spectrometry after ion exchange processes, which has been considered a promising technique for the separation of Li isotopes. One of the concerns in ICP-MS analysis is sodium interference. The presence of sodium in the lithium-containing sample has potential implications for the accuracy of isotopic ratio measurements. For this reason, a method is described for the study of sodium interference in 7Li 295,88%₀ and 303,30%₀ enriched solutions. Methods: For this study, the reference standard L-SVEC was used, it has an isotopic abundance of 92.409% for 7Li and 7.591% for 6Li (6Li/7Li ratio = 0.08251) and solutions enriched at 295,88%₀ (6Li/7Li ratio = 0.06661) and 303,30%₀ (6Li/7Li ratio = 0.06810) of 7Li. Concentrations of 50 μg L-1 of lithium were maintained for the solutions used and it was evaluated with the addition of 50, 100, 300, 450 and 1000 μg L-1 of sodium on the enriched samples suffered significant changes in their isotopic ratio. The ICP-MS used for the sample analysis was a PerkinElmer SCIEX Elan 6000. For the isotopic ratio measurement the parameters used was nebulizer gas flow of approximately 0.94 L min-1 , Radio Frequency (RF) 600 W, gas flow rate 1.2 L min-1 , Peak Hopping mode, dwell time 80 and 480 ms for 6Li and 7Li respectively, 50 sweeps per reading, 1 read per replicate and 10 replicates. Results: For this study, 24 samples were analyzed being divided into four sets of samples with 6 samples each set. The sets were composed of samples without addition of sodium and samples with addition of 50, 100, 300, 450 and 1000 μg L-1 of sodium. The first set of samples, composed of the 295,88%₀ enriched sample, had a standard deviation of 3.59✕10-4. The second set of samples, composed of the 303,30%₀ enriched sample, had a standard deviation of 2.63✕10-4. The third and fourth set of samples, composed of aliquots of the L-SVEC standard, obtained a standard deviation of 2.22✕10-4 e 2.54✕10-4, respectively. Showing that the addition of sodium did not significantly interfere in the ratio of lithium isotopes 6 and 7 according to standard deviation. Conclusions: Through the results obtained from the experiment, it was observed that the variation in the ratio between isotopes 6 and 7 of lithium was not significant for the results of analysis in ICP-MS. However, it should be noted that for the purposes of lithium isotope separation processes using ion exchange resins, the interference of sodium in the chromatographic separation needs to be evaluated.pt_BR
dc.event.siglaIBEROpt_BR
dc.format.extent380-381pt_BR
dc.identifier.citationANDRADE, MARIANA N. de; OTOMO, JULIANA I.; GIMENEZ, MAISE P.; NASCIMENTO, LETICIA da S.; NASCIMENTO, HENRIQUE B. do; LEAO, PAULO H.B.; CECILIO, PRISCILA de S.; FERREIRA, JOAO C.; BERGAMASCHI, VANDERLEI S.; BUSTILLOS, OSCAR V. Sodium interference in lithium isotope ratio analysis by Inductively Coupled Plasma Mass Spectrometry. In: SIMIONATO, ANA V.C. (coord.). In: IBEROAMERICAN CONFERENCE ON MASS SPECTROMETRY, 3rd, December 10-15, 2022, Rio de Janeiro, RJ. <b>Abstract...</b> Campinas, SP: Sociedade Brasileira de Espectrometria de Massas - BrMASS, 2022. p. 380-381. Disponível em: http://repositorio.ipen.br/handle/123456789/33930.
dc.identifier.orcidhttps://orcid.org/0000-0002-4712-4057
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/33930
dc.localCampinas, SPpt_BR
dc.local.eventoRio de Janeiro, RJpt_BR
dc.publisherSociedade Brasileira de Espectrometria de Massas - BrMASSpt_BR
dc.rightsopenAccesspt_BR
dc.titleSodium interference in lithium isotope ratio analysis by Inductively Coupled Plasma Mass Spectrometrypt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorMAISE PASTORE GIMENEZ
ipen.autorLETICIA DA SILVA NASCIMENTO
ipen.autorPAULO HENRIQUE BARRETO LEAO
ipen.autorJOSE OSCAR WILLIAM VEGA BUSTILLOS
ipen.autorVANDERLEI SERGIO BERGAMASCHI
ipen.autorJOAO COUTINHO FERREIRA
ipen.autorPRISCILA DE SOUZA CECILIO
ipen.autorHENRIQUE BATAGLIA DO NASCIMENTO
ipen.autorJULIANA IKEBE OTOMO
ipen.autorMARIANA NOVAIS DE ANDRADE
ipen.codigoautor14539
ipen.codigoautor15867
ipen.codigoautor15893
ipen.codigoautor82
ipen.codigoautor221
ipen.codigoautor489
ipen.codigoautor15895
ipen.codigoautor15648
ipen.codigoautor3924
ipen.codigoautor14829
ipen.contributor.ipenauthorMAISE PASTORE GIMENEZ
ipen.contributor.ipenauthorLETICIA DA SILVA NASCIMENTO
ipen.contributor.ipenauthorPAULO HENRIQUE BARRETO LEAO
ipen.contributor.ipenauthorJOSE OSCAR WILLIAM VEGA BUSTILLOS
ipen.contributor.ipenauthorVANDERLEI SERGIO BERGAMASCHI
ipen.contributor.ipenauthorJOAO COUTINHO FERREIRA
ipen.contributor.ipenauthorPRISCILA DE SOUZA CECILIO
ipen.contributor.ipenauthorHENRIQUE BATAGLIA DO NASCIMENTO
ipen.contributor.ipenauthorJULIANA IKEBE OTOMO
ipen.contributor.ipenauthorMARIANA NOVAIS DE ANDRADE
ipen.date.recebimento23-03
ipen.event.datapadronizada2022pt_BR
ipen.identifier.ipendoc29564pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication2996299a-37aa-403f-949d-6e64bc952d16
relation.isAuthorOfPublication920e733d-d5d3-488c-8d8d-c791d77f4db4
relation.isAuthorOfPublication1d8ac39c-5c37-42e7-9a6e-07c992a87fbf
relation.isAuthorOfPublicationfca54715-9422-40f4-97aa-f96c174fae47
relation.isAuthorOfPublication5d03afd0-2ed9-41bc-9396-ac55d963940d
relation.isAuthorOfPublication2dd18575-cb64-4385-8b4e-1d6f4385e64a
relation.isAuthorOfPublicationae64c1df-3f19-4344-94f3-2d08a05ee2db
relation.isAuthorOfPublicationc7f6756d-022f-475d-8788-5fb80e32a3fd
relation.isAuthorOfPublication57341b35-c8d5-4fa5-a2b4-4f652d9163cf
relation.isAuthorOfPublication40f07e68-1d91-4f78-849e-2a6ecd5c4c82
relation.isAuthorOfPublication.latestForDiscovery40f07e68-1d91-4f78-849e-2a6ecd5c4c82
sigepi.autor.atividadeBUSTILLOS, OSCAR V.:82:520:Npt_BR
sigepi.autor.atividadeBERGAMASCHI, VANDERLEI S.:221:610:Npt_BR
sigepi.autor.atividadeFERREIRA, JOAO C.:489:610:Npt_BR
sigepi.autor.atividadeCECILIO, PRISCILA de S.:15895:610:Npt_BR
sigepi.autor.atividadeLEAO, PAULO H.B.:15893:520:Npt_BR
sigepi.autor.atividadeNASCIMENTO, HENRIQUE B. do:15648:520:Npt_BR
sigepi.autor.atividadeNASCIMENTO, LETICIA da S.:15867:520:Npt_BR
sigepi.autor.atividadeGIMENEZ, MAISE P.:14539:520:Npt_BR
sigepi.autor.atividadeOTOMO, JULIANA I.:3924:520:Npt_BR
sigepi.autor.atividadeANDRADE, MARIANA N. de:14829:520:Spt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
29564.pdf
Tamanho:
379.26 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: