dc.description.abstractAmong the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber, built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-ray beams established for computed tomography at the LCI.pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipIDCNPq: 301335/2016-8pt_BR
dc.description.sponsorshipIDCAPES: 554/2018pt_BR
dc.format.extent1-8pt_BR
dc.identifier.citationCASTRO, MAYSA C.; SILVA, NATALIA F.; CALDAS, LINDA V.E. Performance of an extrapolation chamber in computed tomography standard beams. <b>Brazilian Journal of Radiation Sciences</b>, v. 8, n. 3B, p. 1-8, 2021. DOI: <a href="https://dx.doi.org/10.15392/bjrs.v8i3B.376">10.15392/bjrs.v8i3B.376</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/32072.
dc.identifier.doi10.15392/bjrs.v8i3B.376pt_BR
dc.identifier.fasciculo3Bpt_BR
dc.identifier.issn2319-0612pt_BR
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.percentilfiSem Percentilpt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/32072
dc.identifier.vol8pt_BR
dc.relation.ispartofBrazilian Journal of Radiation Sciencespt_BR
dc.rightsopenAccesspt_BR
dc.sourceMeeting on Nuclear Reactor Physics and Thermal Hydraulics (ENFIR), 20th, October 22-27, 2017, Belo Horizonte, MGpt_BR
dc.subjectcalibration
dc.subjectcomputerized tomography
dc.subjectextrapolation chambers
dc.subjectperformance
dc.subjectradiation doses
dc.subjectsaturation
dc.subjectstability
dc.subjectx radiation
dc.titlePerformance of an extrapolation chamber in computed tomography standard beamspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorNATALIA FIORINI DA SILVA
ipen.autorMAYSA COSTA DE CASTRO
ipen.codigoautor1495
ipen.codigoautor12139
ipen.codigoautor12105
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorNATALIA FIORINI DA SILVA
ipen.contributor.ipenauthorMAYSA COSTA DE CASTRO
ipen.date.recebimento21-08
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc27843pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublicationc8a4b1ff-5955-47b9-a15a-ecbd12a4baa8
relation.isAuthorOfPublicationa7ec93af-7e13-4572-8409-2fcafeab7015
relation.isAuthorOfPublication.latestForDiscoverya7ec93af-7e13-4572-8409-2fcafeab7015
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR
sigepi.autor.atividadeSILVA, NATALIA F.:12139:330:Npt_BR
sigepi.autor.atividadeCASTRO, MAYSA C.:12105:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27843.pdf
Tamanho:
764.07 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções