The influence of unstable signals for electron spin resonance dosimetry with synthetic A-type carbonated apatite
| dc.contributor.author | OLIVEIRA, L.M. | pt_BR |
| dc.contributor.author | ROSSI, A.M. | pt_BR |
| dc.contributor.author | LOPES, R.T. | pt_BR |
| dc.contributor.author | RODRIGUES, L.N. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2014-07-31T11:33:16Z | pt_BR |
| dc.date.accessioned | 2014-07-31T11:54:18Z | |
| dc.date.available | 2014-07-31T11:33:16Z | pt_BR |
| dc.date.available | 2014-07-31T11:54:18Z | |
| dc.date.issued | 2002 | pt_BR |
| dc.description.abstract | Synthetic A-type carbonated apatite prepared in controlled conditions was irradiated at room temperature with 60Co gamma rays. The ESR spectrum was associated to axial CO2- and orthorhombic CO3- species. Radicals used as dose markers in biological apatites are long-lived paramagnetic species. The stability of the post-irradiation signal of A-type apatite was investigated for almost 2 years. Measurements showed variations in the spectra attributed to unstable CO3- species, which can be eliminated by thermal treatments at 100ºC for 24 h. Results indicated the potential use of an A-type carbonated apatite as a dosemeter. | |
| dc.format.extent | 539-544 | pt_BR |
| dc.identifier.citation | OLIVEIRA, L.M.; ROSSI, A.M.; LOPES, R.T.; RODRIGUES, L.N. The influence of unstable signals for electron spin resonance dosimetry with synthetic A-type carbonated apatite. <b>Radiation Protection Dosimetry</b>, v. 101, n. 1/4, p. 539-544, 2002. DOI: <a href="https://dx.doi.org/10.1093/oxfordjournals.rpd.a006044">10.1093/oxfordjournals.rpd.a006044</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/7402. | |
| dc.identifier.doi | 10.1093/oxfordjournals.rpd.a006044 | |
| dc.identifier.fasciculo | 1/4 | pt_BR |
| dc.identifier.issn | 0144-8420 | pt_BR |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/7402 | pt_BR |
| dc.identifier.vol | 101 | pt_BR |
| dc.relation.ispartof | Radiation Protection Dosimetry | pt_BR |
| dc.rights | closedAccess | en |
| dc.subject | apatites | pt_BR |
| dc.subject | calcium phosphates | pt_BR |
| dc.subject | irradiation | pt_BR |
| dc.subject | gamma radiation | pt_BR |
| dc.subject | cobalt 60 | pt_BR |
| dc.subject | electron spin resonance | pt_BR |
| dc.subject | radicals | pt_BR |
| dc.subject | signals | pt_BR |
| dc.subject | stability | pt_BR |
| dc.subject | dosimetry | pt_BR |
| dc.title | The influence of unstable signals for electron spin resonance dosimetry with synthetic A-type carbonated apatite | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | RICARDO T. LOPES | |
| ipen.autor | LAURA NATAL RODRIGUES | |
| ipen.autor | LIANA MACEDO DE OLIVEIRA | |
| ipen.codigoautor | 7316 | |
| ipen.codigoautor | 324 | |
| ipen.codigoautor | 1395 | |
| ipen.contributor.ipenauthor | RICARDO T. LOPES | |
| ipen.contributor.ipenauthor | LAURA NATAL RODRIGUES | |
| ipen.contributor.ipenauthor | LIANA MACEDO DE OLIVEIRA | |
| ipen.date.recebimento | 03-12 | pt_BR |
| ipen.identifier.fi | 0.555 | pt_BR |
| ipen.identifier.ipendoc | 09161 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.range.fi | 0.001 - 1.499 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 88f9935b-7316-44c1-b38d-28afff8b3da6 | |
| relation.isAuthorOfPublication | 11143e67-5715-4371-8f83-c77802e0ef1c | |
| relation.isAuthorOfPublication | ca8f8784-4ddc-4e2d-b69a-d310f2734775 | |
| relation.isAuthorOfPublication.latestForDiscovery | ca8f8784-4ddc-4e2d-b69a-d310f2734775 | |
| sigepi.autor.atividade | OLIVEIRA, L.M.:1395:-1:S | pt_BR |
| sigepi.autor.atividade | ROSSI, A.M.:-1:-1:N | pt_BR |
| sigepi.autor.atividade | pt_BR | |
| sigepi.autor.atividade | LOPES, R.T.:7316:-1:N | pt_BR |
| sigepi.autor.atividade | RODRIGUES, L.N.:324:28:N | pt_BR |
Pacote Original
1 - 1 de 1