Equivalence between Solid Water and printed PLA plates for 6 MV clinical photon beam - An assessment using thermoluminescent dosimetry

dc.contributor.authorVALERIANO, C.C.S.
dc.contributor.authorMORENO, C.S.
dc.contributor.authorCORREA, E.L.
dc.contributor.authorSAKURABA, R.K.
dc.contributor.authorCAMPOS, L.L.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATIONS, 10thpt_BR
dc.date.accessioned2017-10-25T10:22:30Z
dc.date.available2017-10-25T10:22:30Z
dc.date.eventoJuly 09-13, 2017pt_BR
dc.description.abstractThree dimensional models of anatomical structures, produced by rapid prototyping are being adopted for medical application as hemodynamics studies and maxillofacial surgery planning. Models with geometrical accuracy can be achieved using medical images as MRI or CT and produced using polyurethane, polylactic acid and epoxy resins[1]. When a volume of tissue equivalent material is used to simulate an interaction of radiation, this volume is given by the name phantom [2]. Plates with different thickness were printed using a 3D printer using a filament of PLA. As the standard material it was used plates of Solid Water RMI-457. The plates of PLA and Solid Water were irradiated using a Linear Accelarator of 6 MV. For each material were performed irradiations for the same thickness of material, in each of them were used thermoluminescent dosimeters of LiF:Mg,Ti to measure the absorbed dose. This work aims to compare the thermoluminescent (TL) dosimetric behavior of PLA plates printed using a 3D printer and solid water plates in the absorbed dose evaluation using clinical photon beams.pt_BR
dc.event.siglaIRRMApt_BR
dc.format.extent68-68pt_BR
dc.identifier.citationVALERIANO, C.C.S.; MORENO, C.S.; CORREA, E.L.; SAKURABA, R.K.; CAMPOS, L.L. Equivalence between Solid Water and printed PLA plates for 6 MV clinical photon beam - An assessment using thermoluminescent dosimetry. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATIONS, 10th, July 09-13, 2017, Chicago, IL, USA. <b>Abstract...</b> p. 68-68. Disponível em: http://repositorio.ipen.br/handle/123456789/27958.
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/27958
dc.local.eventoChicago, IL, USApt_BR
dc.rightsopenAccesspt_BR
dc.titleEquivalence between Solid Water and printed PLA plates for 6 MV clinical photon beam - An assessment using thermoluminescent dosimetrypt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorEDUARDO DE LIMA CORREA
ipen.autorCAIO CESAR SANTOS VALERIANO
ipen.codigoautor1195
ipen.codigoautor7498
ipen.codigoautor14091
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorEDUARDO DE LIMA CORREA
ipen.contributor.ipenauthorCAIO CESAR SANTOS VALERIANO
ipen.date.recebimento17-10pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc23268pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication1f00087b-0c1b-413b-8464-2842b24a7328
relation.isAuthorOfPublicationafc1c760-7846-46cd-b99b-9af3768ae99e
relation.isAuthorOfPublication.latestForDiscoveryafc1c760-7846-46cd-b99b-9af3768ae99e
sigepi.autor.atividadeVALERIANO, C.C.S.:14091:330:Spt_BR
sigepi.autor.atividadeCORREA, E.L.:7498:330:Npt_BR
sigepi.autor.atividadeCAMPOS, L.L.:1195:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
23268.pdf
Tamanho:
83.87 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: