Quantitative analysis of neonicotinoid insecticide residues in surface water by HPLC-MS / MS

Carregando...
Imagem de Miniatura

Data

Data de publicação

2016

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

É parte de

IBERO AMERICAN CONFERENCE ON MASS SPECTROMETRY, 1st; CONFERENCE OF THE BRAZILIAN MASS SPECTROMETRY SOCIETY, 6th
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
The sudden disappearance of bees in colonies of several countries have attracted the attention of scientists, the public and the world press [1]. This phenomenon was called Colony Collapse Disorder (CCD) and is characterized by a rapid loss of adult bee population. In these colonies, the queen is still alive and accompanied by few adult bees although there are still pups and food in the hive [2]. There are several hypotheses about the causes of this phenomenon; one of them relates a bees exposure for a class of pesticides named neonicotinoids. These are a class of insecticides which began to be produced in 1985 and are based on the nicotine molecule [3]. These insecticides are used to control sucking and chewing insects because of its low toxicity to mammals, fishes and birds, and high toxicity to arthropods, especially insects and crustaceans [4]. The neonicotinoids used in this study are Clothianidin, Imidacloprid and Thiamethoxam. There is no legislation in Brazil to determine the residual limit in water to any of these pesticides, however, the EPA (United States Environmental Protection Agency) has a legislation with limits for each compound. The residual limit for chronic exposures in surface water is 2.1 μg L-1 for Clothianidin [5], 15.8 μg L-1 for Imidacloprid [6] and 0.6 μg L-1 for Thiamethoxam [7]. This study intends to develop and validate a methodology for neonicotinoids in surface water by high performance liquid chromatography with tandem mass spectrometry (HPLC-MS / MS). The samples for this study are surface water collected from a lake in the Bauru country in São Paulo state. The choice of this lake is because its proximity to sugar cane, orange, coffee and watermelon crops. These samples were filtered through a vacuum filtration system and passed through a sample preparation process using the solid phase extraction (SPE). Strata X cartridge was conditioned with methanol - dichloromethane (1:1) and ultrapure water. The water sample was eluted from the cartridge with an alkaline pH range between 9.90 to 10.10, and the analytes of interest were eluted with methanol - dichloromethane (1: 1). The analysis of HPLC-MS / MS used a High Performance Liquid Chromatograph 1100 series by Agilent with an API 2000 mass spectrometer from Sciex. The analysis performed on Multiple Reaction Monitoring (MRM) mode selecting a quantization and confirmation ion for each compound. The quantitation limits are between 1 - 2.5 μg L-1, and the linearity are between 0.991 – 0.997 in this method.

Como referenciar
AMARAL, PRISCILA O.; GIMENEZ, MAISE P.; LEBRE, DANIEL T.; MARQUES, JOYCE R.; BUSTILLOS, OSCAR V. Quantitative analysis of neonicotinoid insecticide residues in surface water by HPLC-MS / MS. In: IBERO AMERICAN CONFERENCE ON MASS SPECTROMETRY, 1st; CONFERENCE OF THE BRAZILIAN MASS SPECTROMETRY SOCIETY, 6th, December 10-14, 2016, Rio de Janeiro, RJ. Abstract... Disponível em: http://repositorio.ipen.br/handle/123456789/27460. Acesso em: 31 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento