Detection of ions by XRF for use in the neonatal clinic

Carregando...
Imagem de Miniatura

Data

Data de publicação

2018

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

É parte de

BRAZILIAN MEETING ON NUCLEAR PHYSICS, 41th
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
In this investigation we intend to introduce bene¯ts to clinical practice in children, especially newborns and premature infants using an alternative procedure based on X-ray °uorescence technology (XRF). The establish- ment of alternative method, focusing on the use of small amounts of blood (a drop) for ions dosage, contributes with actions to humanize health care with minimal su®ering in the sense of adding another alternative for labo- ratory analysis in the pediatric practice. The dimension of this problem can be evaluated when a 3 kg newborn is considered to have between 280 mL and 300 mL of blood, while a preterm of 1 kg is in the range of 180 - 200 mL. As a result, blood collections for laboratory and functional tests in pediatric practice are the main causes of transfusions in infants, especially premature babies, depending on the dysfunction or treatment the child may need two to three collections per day. Based on these facts, the objective of this work is to analyze blood of newborns, concomitant with the traditional collection ("foot test"). The Ca, Cl, Fe and K dosage in blood samples of were determined using XRF technique. The blood samples came from the nursery of the Hospital of Itapecirica da Serra (S~ao Paulo city, Brazil). The X-Ray Fluorescence analysis was performed using X-Ray Spectrometer (X-123 SDD model - Amptek). The XRF analytical technique showed to be appropriate o®ering a new contribution to the neonatal clinic with actions to humanize health care, guaranteeing diagnostic accuracy with minimal su®ering and exposure to risks in the pediatric practice.

Como referenciar
ZAMBONI, C.B.; SOUZA, G.O.; ALVARENGA, A.M.; GIOVANNI, D.N.S.; AZEVEDO, M.R.; KONSTANTYNER, T. Detection of ions by XRF for use in the neonatal clinic. In: BRAZILIAN MEETING ON NUCLEAR PHYSICS, 41th, September 2-6, 2018, Maresias, SP. Abstract... São Paulo: Sociedade Brasileira de Física, 2018. p. 1-1. Disponível em: http://repositorio.ipen.br/handle/123456789/30115. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento